超声微泡增强万古霉素对体内表皮葡萄球菌生物膜的活性
在兔模型中皮下植入预先生成表皮葡萄球菌生物膜的聚四氟乙烯导管,随机分组比较超声联合微泡与万古霉素的协同作用;超声加微泡加万古霉素组导管内细菌量从对照组6.44±0.03 log10 CFU/导管降至3.49±0.02 log10 CFU/导管(P<.001),扫描电镜下生物膜厚度和细菌密度降低更明显,组织病理学检查未见器官和皮肤异常。
要点
- 超声加微泡可将万古霉素对导管生物膜的杀菌效果从6.44±0.03降至3.49±0.02 log10 CFU/导管(P<.001)。
- 扫描电镜下超声加微泡加万古霉素组生物膜厚度和细菌密度降低程度大于其他治疗组。
- 组织病理学检查显示心脏、肾脏、肝脏和皮下组织未见异常。
核心结论
- 超声微泡增强了万古霉素对体内表皮葡萄球菌生物膜的抗菌效果,且未对动物造成明显伤害。
研究设计与样本
- 兔模型研究,每只兔脊柱两侧各植入一根预先生成表皮葡萄球菌生物膜的聚四氟乙烯导管,自身对照并随机分组;超声参数为300 kHz、0.5 W/cm²、50%占空比,术后24至72小时每天2次,联合或不联合皮下注射微泡;终点为扫描电镜检查和细菌计数,心、肾、肝及皮下组织送组织病理学检查。
关键影像表现/征象
- 扫描电镜下,超声加微泡加万古霉素组生物膜厚度和细菌密度降低程度大于其他治疗组。
- 组织病理学检查显示心脏、肾脏、肝脏和皮肤未见异常。
诊断标准与关键数值
- 对照组导管细菌量均值±标准差为6.44±0.03 log10 CFU/导管。
- 超声加微泡加万古霉素组导管细菌量均值±标准差为3.49±0.02 log10 CFU/导管,与对照组比较P<.001。
- 超声加微泡加万古霉素组抗菌效果优于超声加万古霉素组,P<.001。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Staphylococcus epidermidis is the predominant pathogen of device-associated infections. By forming biofilms on the device surface, S epidermidis has substantial resistance to antibiotics and is difficult to eradicate. This study aimed to explore the synergistic effect of ultrasound (US)-mediated microbubbles combined with vancomycin on S epidermidis biofilms in a rabbit model.
METHODS: Two polytetrafluoroethene catheters with preformed S epidermidis biofilms were implanted subcutaneously in a rabbit, one on either side of the spine. Animals were randomized into different treatment groups, with each rabbit acting as its own control and treatment. Ultrasound was applied from 24 to 72 hours after surgery 2 times a day. The parameters were 300 kHz and 0.5 W/cm2 in a 50% duty cycle, with or without microbubbles injected subcutaneously into the implantation site. After treatments, animals were euthanized, and implants were removed for a scanning electron microscopic examination and bacterial counting. The hearts, kidneys, livers, and subcutaneous tissues were sent for histopathologic examinations.
RESULTS: Ultrasound + microbubbles increased the bactericidal action of vancomycin by decreasing biofilm viability from a mean ± SD of 6.44 ± 0.03 log10 colony-forming units per catheter in the control group to 3.49 ± 0.02 log10 colony-forming units per catheter in US + microbubble + vancomycin group (P < .001). The antibacterial effect of US + microbubbles + vancomycin was more pronounced than that of US + vancomycin (P < .001). Under scanning electron microscopy, biofilms exposed to US + microbubbles + vancomycin showed a greater reduction in thickness and bacterial density than other treatments. Histopathologic examinations showed no abnormalities in organs and skins.
CONCLUSIONS: Ultrasound microbubbles enhanced the antibacterial effect of vancomycin against S epidermidis biofilms in vivo without exerting obvious harms to the animals.
引用
- Dong Y, Li J, Li P, et al. Ultrasound Microbubbles Enhance the Activity of Vancomycin Against Staphylococcus epidermidis Biofilms In Vivo. J Ultrasound Med. 2017. PMID: 29159979. doi:10.1002/jum.14475