技术进展:肩关节零回波时间成像——利用MR成像提高骨性细节显示
本研究纳入34例同时接受标准诊疗MRI和CT检查的患者,比较CT与零回波时间(ZTE)MR成像在肩关节形态学分级和临床相关定量测量中的一致性。结果显示两种方法间一致性较高(κ或ICC>0.6),且21/34例ZTE图像对骨性特征的显示优于标准MRI。ZTE可提供「类CT」骨对比,提示在某些情况下可替代CT用于临床。
要点
- ZTE MR成像可提供「类CT」骨对比,与CT在肩关节形态学分级和定量测量间一致性较高。
- ZTE对附着点囊肿和骨髓水肿的显示比标准MRI更明显。
- 21/34例ZTE图像对骨性特征的显示优于标准MRI,提示部分病例可替代CT。
核心结论
- ZTE MR成像提供「类CT」骨对比,与CT测量和分级一致性较强,多数ZTE图像对骨性特征显示优于标准MRI,提示某些情况下可临床替代CT。
研究设计与样本
- 经机构审查委员会批准的研究,纳入34例接受标准诊疗MR成像并同期行CT检查的患者,在标准MR后采集ZTE图像,比较CT与ZTE对肩关节形态、损伤/疾病及手术史的评级或测量。
关键影像表现/征象
- ZTE对附着点囊肿和骨髓水肿的显示比标准MRI更明显;21/34例ZTE图像对骨性特征的显示优于标准MRI。
诊断标准与关键数值
- 二分类及名义/序数分级在评估者间和两种方法间呈中等以上一致性(κ或ICC>0.6);连续测量在评估者间和两种方法间呈强相关,但并非普遍如此;Bankart损伤ICC因患病率低而未达显著。
临床应用与阅片要点
- ZTE可提供「类CT」骨对比,与CT定量测量一致性较强;多数ZTE图像对骨性特征显示优于标准MRI,提示某些情况下可临床替代CT。
局限性
- Bankart损伤ICC因患病率低而未达显著。
- 连续测量在评估者间和两种方法间呈强相关,但并非普遍如此。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To determine the intermodality agreement of morphologic grading and clinically relevant quantitative measurements between computed tomography (CT) and zero echo time (ZTE) magnetic resonance (MR) imaging of the shoulder. The primary objective was to demonstrate the clinical applicability of ZTE in osseous shoulder imaging. Materials and Methods Thirty-four patients undergoing standard-of-care (SOC) MR imaging with concomitant CT were enrolled in this institutional review board-approved study. ZTE images were acquired after SOC MR imaging. Glenoid morphology (version, vault depth, erosion), injury or disease (osteoarthritis, Bankart and Hill-Sachs lesions, subchondral cysts), and evidence of prior surgery were graded or measured. κ Values, intraclass correlation coefficients (ICCs), and Bland-Altman limits of agreement were used to establish agreement. Qualitative comparison of osseous findings was performed between ZTE and SOC MR imaging. Results Binary classification and nominal/ordinal grades showed substantial or better agreement between raters and modalities (κ or ICC > 0.6). Continuous measurements exhibited strong correlation between raters and modalities, although not universally. Bankart ICCs were not significant, owing to low prevalence. ZTE exhibited greater conspicuity of enthesopathic cysts and marrow edema. In 21 of 34 cases, ZTE imaging of osseous features exceeded SOC MR imaging. Conclusion ZTE MR imaging provides "CT-like" contrast for bone. The results of this study demonstrate strong intermodality agreement between measurements and grades from CT and ZTE images in a cohort of patients undergoing imaging with both modalities. A majority of ZTE image sets provided superior visualization of osseous features when compared with SOC MR image sets. This superiority coupled with strong quantitative agreement with CT suggests that ZTE may be used clinically in lieu of CT in some cases. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Breighner RE, Endo Y, Konin GP, et al. Technical Developments: Zero Echo Time Imaging of the Shoulder: Enhanced Osseous Detail by Using MR Imaging. Radiology. 2017. PMID: 29117482. doi:10.1148/radiol.2017170906
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。