文献速递骨肌神经MR

骨髓转移瘤:T2加权Dixon自旋回波脂肪图像可替代T1加权自旋回波图像

Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images.
PubMed 文献 · Radiology · 2017-11-02

本回顾性研究纳入121例疑似椎体骨转移的全脊柱MR检查,比较替代方案(矢状面自旋回波Dixon T2加权脂肪-only和水-only成像)与标准方案(矢状面自旋回波T1加权和自旋回波Dixon T2加权水-only成像)的诊断性能。替代方案对比噪声比显著更高(181.1 vs 84.7,P < .001),诊断性能不劣于标准方案,患者水平敏感度97.9%-98.9% vs 93.6%-97.9%,特异度85.2%-92.6% vs 92.6%-96.3%,AUC 0.92-0.96 vs 0.95(所有P ≤ .02)。结论认为Dixon T2加权脂肪-only和水-only成像在一个序列中提供与标准形态学序列组合相似的诊断性能,可减少成像时间。

要点

  • 替代方案对比噪声比显著高于标准方案(181.1 vs 84.7,P < .001)。
  • 患者水平敏感度替代方案97.9%-98.9% vs 标准方案93.6%-97.9%,特异度85.2%-92.6% vs 92.6%-96.3%。
  • Dixon T2加权脂肪-only和水-only成像可减少成像时间,因无需T1序列。

核心结论

  • Dixon T2加权脂肪-only和水-only成像在一个序列中提供与标准形态学序列组合相似的诊断性能,可用于检测可能的脊柱骨转移,并有机会通过消除T1序列来减少成像时间。

研究设计与样本

  • 回顾性、机构审查委员会批准的研究,纳入121例连续全脊柱MR检查(63名男性;平均年龄±标准差,61.4岁±11.8),用于疑似椎体骨转移;定量图像分析随机选取30个脊柱水平,定性分析由两名肌骨放射科医生分别独立进行并记录每个脊柱水平的转移瘤数量;以最佳价值比较器为参考,采用非参数受试者工作特征曲线估计对配对数据进行非劣效性检验比较AUC,使用κ统计评估观察者间和方案间一致性。

关键影像表现/征象

  • 替代方案图像的对比噪声比显著高于标准方案图像(181.1 [95%CI: 140.4, 221.7] vs 84.7 [95%CI: 66.3, 103.1];P < .001)。

诊断标准与关键数值

  • 患者水平分析:替代方案敏感度97.9%-98.9% vs 标准方案93.6%-97.9%,特异度85.2%-92.6% vs 92.6%-96.3%,AUC 0.92-0.96 vs 0.95(所有P ≤ .02)。
  • 脊柱水平分析:替代方案诊断性能不劣于标准方案(所有P < .01)。
  • 观察者间和方案间一致性良好至非常好(κ = 0.70-0.81)。

临床应用与阅片要点

  • Dixon T2加权脂肪-only和水-only成像可在单个序列中提供与标准T1加权联合Dixon T2加权水-only序列相似的诊断性能,可能减少成像时间。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To test the potential of Dixon T2-weighted fat-only sequences to replace T1-weighted sequences for the detection of bone metastases, with the hypothesis that diagnostic performance with an alternative magnetic resonance (MR) imaging protocol (sagittal spin-echo Dixon T2-weighted fat-only and water-only imaging) would not be inferior to that with the standard protocol (sagittal spin-echo T1-weighted and spin-echo Dixon T2-weighted water-only imaging). Materials and Methods A total of 121 consecutive whole-spine MR imaging examinations (63 men; mean age ± standard deviation, 61.4 years ± 11.8) performed for suspected vertebral bone metastases were included in this retrospective, institutional review board-approved study. Quantitative image analysis was performed for 30 randomly selected spine levels. Qualitative analysis was performed separately by two musculoskeletal radiologists, who registered the number of metastases for each spine level. Areas under the curve with the protocols were compared on the basis of nonparametric receiver operating characteristic curve estimations by using a noninferiority test on paired data, with a best valuable comparator as a reference. Interobserver and interprotocol agreement was assessed by using κ statistics. Results Contrast-to-noise ratio was significantly higher on the alternative protocol images than on the standard protocol images (181.1 [95% confidence interval: 140.4, 221.7] vs 84.7 [95% confidence interval: 66.3, 103.1] respectively; P < .001). Diagnostic performance was not significantly inferior with the alternative protocol than with the standard protocol for both readers in a per-patient analysis (sensitivity, 97.9%-98.9% vs 93.6%-97.9%; specificity, 85.2%-92.6% vs 92.6%-96.3%; area under the curve, 0.92-0.96 vs 0.95, respectively; all P ≤ .02) and a per-spine level analysis (all P < .01). Interobserver and interprotocol agreement was good to very good (κ = 0.70-0.81). Conclusion Dixon T2-weighted fat-only and water-only imaging provide, in one sequence, diagnostic performance similar to that of the standard combination of morphologic sequences for the detection of probable spinal bone metastases, thereby providing an opportunity to reduce imaging time by eliminating the need to perform T1 sequences. © RSNA, 2017 An earlier incorrect version of this article appeared online. This article was corrected on November 6, 2017.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Maeder Y, Dunet V, Richard R, et al. Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images. Radiology. 2017. PMID: 29095674. doi:10.1148/radiol.2017170325

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。