文献速递头颈甲状腺与浅表US

小于1.0 cm甲状腺结节的细针穿刺活检:TIRADS分类系统在超过1000个结节中的准确性

Fine needle aspiration biopsy of thyroid nodule smaller than 1.0 cm: accuracy of TIRADS classification system in more than 1000 nodules.
PubMed 文献 · Br J Radiol · 2017-12-22

单机构回顾性研究纳入2008至2016年1094个小于1.0 cm的甲状腺结节,按TIRADS分类并接受细针穿刺活检,比较超声标准与细胞学结果。各TIRADS分类中恶性比例分别为:2类0.91%、3类2.87%、4A类12.26%、4B类34.43%、4C类66.6%、5类85.7%。结论认为基于本文所述超声特征的TIRADS分类系统可能有助于识别需要进一步检查的潜在恶性结节。

要点

  • 小于1.0 cm甲状腺结节中,TIRADS 2类恶性比例0.91%,3类2.87%。
  • TIRADS 4A类恶性比例12.26%,4B类34.43%。
  • TIRADS 4C类恶性比例66.6%,5类85.7%。

核心结论

  • TIRADS分类系统基于本文报告的超声特征,可能有助于检测哪些结节应被进一步检查以排查潜在恶性。

研究设计与样本

  • 单机构、经IRB批准的回顾性研究,2008至2016年评估1094个小于1.0 cm的甲状腺结节,按TIRADS分类并提交细针穿刺活检,将穿刺结果与细胞学发现进行对比。

关键影像表现/征象

  • 按TIRADS分类统计的恶性比例:2类0.91%,3类2.87%。
  • 按TIRADS分类统计的恶性比例:4A类12.26%,4B类34.43%。
  • 按TIRADS分类统计的恶性比例:4C类66.6%,5类85.7%。

诊断标准与关键数值

  • TIRADS 2类结节中恶性比例为0.91%。
  • TIRADS 3类结节中恶性比例为2.87%。
  • TIRADS 4A类结节中恶性比例为12.26%。
  • TIRADS 4B类结节中恶性比例为34.43%。
  • TIRADS 4C类结节中恶性比例为66.6%,5类结节中恶性比例为85.7%。

临床应用与阅片要点

  • 作者认为,基于本文所述超声特征的TIRADS分类系统可能有助于识别需要进一步检查的潜在恶性结节。
  • 作者指出,该亚组结节中恶性发现的结论可能有助于临床随访中判断哪些患者应接受早期影像学评估或干预。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To identify whether or not the same ultrasound features can be applied and should be considered to support the decision as to which subcentimeter nodules should be biopsied with fine needle aspiration (FNAB).

METHODS: Single-institution, IRB approved, retrospective study conducted from 2008 to 2016 that evaluated 1094 thyroid nodules smaller than 1.0 cm that were classified according to TIRADS and submitted for FNAB.

RESULTS: The value of FNAB of thyroid nodules smaller than 1.0 cm were assessed and correlated with the sonographic criteria by comparing the obtained results with the cytological findings in 1094 thyroid nodules. In the analysis considering all nodules, the proportion of malignancies among nodules with TIRADS 2 is 0.91% and for TIRADS 3 is 2.87%. Among those classified as 4A, 12.26%; with 4B classification, 34.43%; with 4C classification, 66.6%; and among those with 5 classifications, 85.7%.

CONCLUSION: In conclusion, the TIRADS classification system, based on the sonographic features reported herein, may help detect which nodules should be investigated for potential malignancies. Advances in knowledge: Few reports compare the efficacy of ultrasound-FNAB for thyroid nodules smaller than 1.0 cm in diameter. The findings of malignancy in this subgroup of nodules may help in the clinical follow-up of which patients should be submitted to an early imaging evaluation or intervention.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Mendes GF, Garcia MR, Falsarella PM, et al. Fine needle aspiration biopsy of thyroid nodule smaller than 1.0 cm: accuracy of TIRADS classification system in more than 1000 nodules. Br J Radiol. 2017. PMID: 29182368. doi:10.1259/bjr.20170642

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。