文献速递乳腺MR

体素内不相干运动与定量非高斯扩散MR成像:评估乳腺良恶性病变多种标志物的诊断与预后价值

Intravoxel Incoherent Motion and Quantitative Non-Gaussian Diffusion MR Imaging: Evaluation of the Diagnostic and Prognostic Value of Several Markers of Malignant and Benign Breast Lesions.
PubMed 文献 · Radiology · 2017-11-02

研究前瞻性纳入199例乳腺病变患者(训练集99例、验证集100例),比较IVIM与非高斯扩散参数联合阈值法和贝叶斯分析与BI-RADS的诊断效能。联合阈值法及贝叶斯分析可获得与BI-RADS几乎相当的评分,且非高斯扩散参数在生物学预后因素间存在差异。

要点

  • IVIM与非高斯扩散参数(ADC0、K、fIVIM、fIVIM·D*、sADC200-1500、ADC0-800)在乳腺良恶性病变间差异有统计学意义(P < .05)。
  • 验证集中联合阈值法敏感度94.7%和96.1%、特异度75.0%和66.7%(放射科医师A和B),与BI-RADS(敏感度100%、特异度79.2%)接近。
  • sADC200-1500在孕激素受体状态间差异有统计学意义(P = .002),在不同组织学亚型间差异有统计学意义(P = .006)。

核心结论

  • 联合多种IVIM与非高斯扩散MR成像参数的方法可能提供与BI-RADS分类几乎相当的评分,且无需使用对比剂;非高斯扩散参数也因生物学预后因素而异。

研究设计与样本

  • 前瞻性研究,2013年5月至2015年3月共411例患者入组,最终纳入199例(训练集99例、验证集100例),采用16个b值(最高2500 sec/mm2)的扩散加权成像序列估算IVIM与非高斯扩散参数并与BI-RADS比较。

诊断标准与关键数值

  • 验证集中sADC200-1500的敏感度94.7%和89.5%、特异度75.0%和79.2%(放射科医师A和B);联合阈值法敏感度94.7%和96.1%、特异度75.0%和66.7%;贝叶斯分析敏感度92.1%和92.1%、特异度83.3%和66.7%;BI-RADS敏感度100%、特异度79.2%。

临床应用与阅片要点

  • 作者认为联合IVIM与非高斯扩散MR成像参数的方法可能提供与BI-RADS分类几乎相当、无需对比剂的评分;非高斯扩散参数在孕激素受体状态(P = .002)和组织学亚型(P = .006)间存在差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the performance of integrated approaches that combined intravoxel incoherent motion (IVIM) and non-Gaussian diffusion parameters compared with the Breast Imaging and Reporting Data System (BI-RADS) to establish multiparameter thresholds scores or probabilities by using Bayesian analysis to distinguish malignant from benign breast lesions and their correlation with molecular prognostic factors. Materials and Methods Between May 2013 and March 2015, 411 patients were prospectively enrolled and 199 patients (allocated to training [n = 99] and validation [n = 100] sets) were included in this study. IVIM parameters (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion parameters (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm2 [ADC0] and kurtosis [K]) by using IVIM and kurtosis models were estimated from diffusion-weighted image series (16 b values up to 2500 sec/mm2), as well as a synthetic ADC (sADC) calculated by using b values of 200 and 1500 (sADC200-1500) and a standard ADC calculated by using b values of 0 and 800 sec/mm2 (ADC0-800). The performance of two diagnostic approaches (combined parameter thresholds and Bayesian analysis) combining IVIM and diffusion parameters was evaluated and compared with BI-RADS performance. The Mann-Whitney U test and a nonparametric multiple comparison test were used to compare their performance to determine benignity or malignancy and as molecular prognostic biomarkers and subtypes of breast cancer. Results Significant differences were found between malignant and benign breast lesions for IVIM and non-Gaussian diffusion parameters (ADC0, K, fIVIM, fIVIM · D*, sADC200-1500, and ADC0-800; P < .05). Sensitivity and specificity for the validation set by radiologists A and B were as follows: sensitivity, 94.7% and 89.5%, and specificity, 75.0% and 79.2% for sADC200-1500, respectively; sensitivity, 94.7% and 96.1%, and specificity, 75.0% and 66.7%, for the combined thresholds approach, respectively; sensitivity, 92.1% and 92.1%, and specificity, 83.3% and 66.7%, for Bayesian analysis, respectively; and sensitivity and specificity, 100% and 79.2%, for BI-RADS, respectively. The significant difference in values of sADC200-1500 in progesterone receptor status (P = .002) was noted. sADC200-1500 was significantly different between histologic subtypes (P = .006). Conclusion Approaches that combined various IVIM and non-Gaussian diffusion MR imaging parameters may provide BI-RADS-equivalent scores almost comparable to BI-RADS categories without the use of contrast agents. Non-Gaussian diffusion parameters also differed by biologic prognostic factors. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Iima M, Kataoka M, Kanao S, et al. Intravoxel Incoherent Motion and Quantitative Non-Gaussian Diffusion MR Imaging: Evaluation of the Diagnostic and Prognostic Value of Several Markers of Malignant and Benign Breast Lesions. Radiology. 2017. PMID: 29095673. doi:10.1148/radiol.2017162853

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。