文献速递乳腺技术与安全乳腺X线

利用电子触发器识别乳腺X线摄影随访延迟:发挥医疗大数据的力量

Electronic Triggers to Identify Delays in Follow-Up of Mammography: Harnessing the Power of Big Data in Health Care.
PubMed 文献 · J Am Coll Radiol · 2017-11-01

研究开发电子触发器算法,基于电子健康记录数据检测乳腺X线异常结果随访延迟(BI-RADS 0、4、5超过60天,BI-RADS 3超过7个月),并对 flagged 记录进行人工复核以评估触发器性能。在365,686例患者中,触发器识别2,129例乳腺X线异常患者,其中552例被标记为随访延迟;随机抽取400份记录复核,确认283例真延迟(阳性预测值71%,95%CI 66%-75%),27%的外院乳腺X线报告存在转录和报告不一致,仅84%记录有患者被告知异常结果的具体文档。结论认为尽管联邦法律要求30天内通知患者乳腺X线结果,护理延迟似乎仍持续存在,触发器临床应用有助于检测这些延迟。

要点

  • 触发器阳性预测值71%(95%CI 66%-75%),可辅助识别乳腺X线随访延迟。
  • 27%的外院乳腺X线报告存在转录和报告不一致。
  • 仅84%记录有患者被告知异常结果的具体文档。

核心结论

  • 尽管联邦法律要求30天内通知患者乳腺X线结果,随访延迟似乎仍持续存在,乳腺X线相关触发器的临床应用有助于检测这些延迟。

研究设计与样本

  • 研究开发算法利用电子健康记录临床数据检测乳腺X线异常结果随访延迟(BI-RADS 0、4、5超过60天,BI-RADS 3超过7个月),对标记记录进行人工复核以评估触发器性能特征,并评估延迟频率、患者沟通、缺乏随访原因及后续乳腺癌诊断;2010年1月1日至2015年5月31日期间共365,686例患者。

诊断标准与关键数值

  • BI-RADS 0、4、5随访延迟定义为超过60天,BI-RADS 3定义为超过7个月。
  • 触发器阳性预测值71%(95%CI 66%-75%),基于随机抽取400份标记记录复核确认283例真延迟。
  • 283例真延迟中280份记录无任何记录计划,3例有计划但未遵守。
  • 27%的外院乳腺X线报告存在转录和报告不一致。
  • 仅335份记录(84%)包含患者被告知异常结果的具体文档。

临床应用与阅片要点

  • 触发器可辅助检测乳腺X线随访延迟,人工复核标记记录可确认真延迟。
  • 外院乳腺X线报告需注意转录和报告不一致的可能。
  • 报告或记录中应包含患者被告知异常结果的具体文档。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We previously developed electronic triggers to automatically flag records for patients experiencing potential delays in diagnostic evaluation for certain cancers. Because of the unique clinical, logistic, and legal aspects of mammography, this study was conducted to evaluate the effectiveness of a trigger to flag delayed follow-up on mammography.

METHODS: An algorithm was developed to detect delays in follow-up of abnormal mammographic results (>60 days for BI-RADS® 0, 4, and 5 and >7 months for BI-RADS 3) using clinical data in the electronic health record. Flagged records were then manually reviewed to determine the trigger's performance characteristics (positive and negative predictive value, sensitivity, and specificity). The frequency of delays and patient communication related to abnormal results, reasons for lack of follow-up, and whether patients were subsequently diagnosed with breast cancer were also assessed.

RESULTS: Of 365,686 patients seen between January 1, 2010, and May 31, 2015, the trigger identified 2,129 patients with abnormal findings on mammography, of whom it flagged 552 as having delays in follow-up. From these, review of 400 randomly selected records revealed 283 true delays (positive predictive value, 71%; 95% confidence interval, 66%-75%), including 280 records without any documented plan and three patients with plans that were not adhered to. Transcription and reporting inconsistencies were identified in 27% of externally performed mammographic reports. Only 335 records (84%) contained specific documentation that the patient was informed of the abnormal result.

CONCLUSIONS: Care delays appear to continue despite federal laws requiring patient notification of mammographic results within 30 days. Clinical application of mammography-related triggers could help detect these delays.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Murphy DR, Meyer AND, Vaghani V, et al. Electronic Triggers to Identify Delays in Follow-Up of Mammography: Harnessing the Power of Big Data in Health Care. J Am Coll Radiol. 2017. PMID: 29102539. doi:10.1016/j.jacr.2017.10.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。