超声超微血管成像评估乳腺肿瘤血管性的效用:与彩色及能量多普勒成像诊断效能的比较
回顾性纳入166例女性191个活检证实乳腺肿块(良性99个、恶性92个),比较超微血管成像(SMI)与彩色多普勒、能量多普勒超声评估肿瘤血管性的价值;SMI血管评分高于彩超/能量多普勒且恶性高于良性(p<0.001),灰阶超声联合SMI的AUC为0.815,高于单纯灰阶超声的0.774及联合彩色多普勒的0.789、联合能量多普勒的0.791(p<0.001)。
要点
- SMI对乳腺肿块血管性的评分高于彩色多普勒和能量多普勒超声。
- SMI总体血管评分最佳截断值为5分,敏感度82.3%、特异度65.3%(AUC 0.808)。
- 灰阶超声联合SMI诊断效能AUC 0.815,高于联合彩色多普勒0.789或能量多普勒0.791。
核心结论
- SMI在描述乳腺肿块血管性方面优于彩色多普勒或能量多普勒超声,并能提高诊断效能。
研究设计与样本
- 回顾性研究,纳入166例女性共191个活检证实的乳腺肿块(良性99个、恶性92个),均行灰阶超声、彩色多普勒、能量多普勒及SMI检查。
- 由三名放射科医师采用三因素评分系统评估肿瘤血管的数目、形态和分布。
- 分别评估单纯灰阶超声及灰阶超声联合各类型血管超声的BI-RADS分类。
- 采用Kruskal-Wallis检验,并测量受试者工作特征曲线下面积(AUC)。
关键影像表现/征象
- SMI显示乳腺肿块的血管评分高于彩色多普勒和能量多普勒超声。
- SMI上恶性肿块的血管评分高于良性肿块(p<0.001)。
诊断标准与关键数值
- SMI总体血管评分最佳截断值为5分,敏感度82.3%、特异度65.3%(AUC 0.808)。
- 灰阶超声联合SMI的AUC为0.815,高于单纯灰阶超声的0.774、灰阶联合彩色多普勒的0.789及灰阶联合能量多普勒的0.791(p<0.001)。
临床应用与阅片要点
- 在乳腺肿块血管性评估中,SMI可较彩色多普勒或能量多普勒超声提供更高的血管评分并改善诊断效能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance.
MATERIALS AND METHODS: A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined.
RESULTS: SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (p<0.001). The diagnostic performance of the combination of greyscale US and SMI was higher than those of greyscale US alone and greyscale and colour or power Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; p<0.001). The optimal cut-off value of the overall vascular score was 5 with a sensitivity of 82.3% and a specificity of 65.3% (AUC, 0.808).
CONCLUSION: SMI is superior to colour or power Doppler US for characterising the vascularity in breast masses and improving diagnostic performance.
引用
- Park AY, Seo BK, Woo OH, et al. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance. Clin Radiol. 2017. PMID: 29122223. doi:10.1016/j.crad.2017.10.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。