双年度数字乳腺X线筛查中导管原位癌的检出率:影像学表现支持肿瘤进展的病理模型
该研究基于1970例分级纯导管原位癌,比较基线筛查与后续两轮数字乳腺X线筛查中不同核级别导管原位癌的检出率。低级别导管原位癌在后续轮次检出率显著降低,中级别降低幅度较小,高级别则持续保持高位,提示不同级别病变进展动力学存在差异。
要点
- 高级别导管原位癌在基线及后续两轮筛查中检出率持续处于高位。
- 低级别导管原位癌在后续筛查轮次检出率显著低于基线筛查。
- 中级别导管原位癌检出率降低幅度小于低级别,但仍具统计学意义。
核心结论
- 与基线筛查相比,高级别导管原位癌在连续两轮后续筛查中检出率持续保持高位;低级别及较低程度的中级别导管原位癌在后续轮次检出率下降,级别相关的检出率变化提示病变进展动力学存在差异。
研究设计与样本
- 基于人群的数字乳腺X线筛查项目分析,纳入16个筛查区域共1970例经分级的纯导管原位癌,筛查轮次间隔22-30个月,采用年龄校正逻辑回归比较基线筛查(参照)与后续两轮各级别检出率。
诊断标准与关键数值
- 低级别导管原位癌每1000名受检妇女检出率范围0.11(58/508817)至0.25(178/713867)。
- 高级别导管原位癌每1000名受检妇女检出率范围0.53(271/508817)至0.59(237/398944)。
- 低级别导管原位癌后续第一轮OR=0.45(P<.001)、第二轮OR=0.57(P<.001),均低于基线筛查。
- 中级别导管原位癌后续第一轮OR=0.79(P=.006)、第二轮OR=0.76(P=.003),降低幅度小于低级别。
- 高级别导管原位癌后续第一轮OR=0.89(P=.143)、第二轮OR=0.97(P=.700),与基线筛查相比未达统计学显著。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare detection rates of ductal carcinoma in situ (DCIS), classified according to nuclear grade, between the prevalence round (baseline screening) and two subsequent screening rounds of a population-based digital mammography screening program, to assess differences over time. Materials and Methods The cancer registry provided data for 1970 graded pure DCIS cases from 16 screening regions of the prevalence round (baseline screening, from 2005 to 2008), first subsequent round, and second subsequent round; the interval between all screening rounds was 22-30 months. Age-adjusted logistic regression analysis was performed to compare the grade-specific detection rates between the prevalence round (reference) and subsequent screening rounds. Results Over all screening rounds, cancer detection rates were lowest for low-grade DCIS (range, 0.11 [58 of 508 817 patients] to 0.25 [178 of 713 867 patients] per 1000 women screened) and highest for high-grade DCIS (range, 0.53[271 of 508 817 patients] to 0.59 [237 of 398 944 patients] per 1000 women screened). Detection rates for low-grade DCIS were significantly lower in the first (odds ratio [OR] = 0.45, P < .001) and second (OR = 0.57, P < .001) subsequent screening rounds compared with that in the prevalence round; the relative reduction of detection rates of intermediate-grade DCIS was less pronounced (OR = 0.79, P = .006 and OR = 0.76, P = .003, respectively). Conversely, the detection rate of high-grade DCIS remained at the high level found in the prevalence screening (OR = 0.89, P = .143 and OR = 0.97, P = .700, respectively). Conclusion The findings demonstrate persistently high detection rates of high-grade DCIS in two consecutive subsequent screening rounds compared with the prevalence round; conversely, rates of low-grade DCIS and, less markedly, intermediate-grade DCIS decreased in subsequent rounds. Grade-related changes of DCIS detection are suggestive of distinct dynamics of lesion progression. © RSNA, 2017 An earlier incorrect version of this article appeared online. This article was corrected on November 10, 2017.
引用
- Weigel S, Khil L, Hense HW, et al. Detection Rates of Ductal Carcinoma in Situ with Biennial Digital Mammography Screening: Radiologic Findings Support Pathologic Model of Tumor Progression. Radiology. 2017. PMID: 29106821. doi:10.1148/radiol.2017170673
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。