筛查性数字乳腺X线摄影召回率:是否会随数字乳腺断层摄影经验而改变?
该回顾性研究分析了2009至2014年间108 276例数字乳腺X线摄影筛查(DBT经验前50 062例,经验后58 214例),比较6名放射科医生在获得DBT经验前后的召回率、癌症检出率(CDR)及阳性预测值(PPV)。结果显示,获得DBT经验后,召回率从6.8%升至7.9%(P=0.0316),CDR从2.5/1000升至3.5/1000(P=0.0203),PPV2从26.9%升至36.1%(P=0.0212),PPV3从31.2%升至40.0%(P=0.0290)。
要点
- 获得DBT经验后,数字乳腺X线摄影的召回率由6.8%升至7.9%(P=0.0316)。
- 获得DBT经验后,CDR由2.5/1000升至3.5/1000(P=0.0203)。
- 获得DBT经验后,PPV2由26.9%升至36.1%,PPV3由31.2%升至40.0%。
核心结论
- 放射科医生获得DBT经验后,数字乳腺X线摄影的召回率、CDR、PPV2和PPV3均升高。
研究设计与样本
- 回顾性研究,经机构审查委员会批准并符合HIPAA,分析2009至2014年108 276例数字乳腺X线摄影筛查(DBT经验前50 062例,经验后58 214例),6名放射科医生在社区机构和两个三级乳腺影像中心工作,采用广义线性混合模型嵌套观察值,P<0.05为差异有统计学意义,计算95%CI。
诊断标准与关键数值
- DBT经验前平均召回率6.8%(范围3.6%-9.7%),经验后7.9%(范围5.5%-9.5%),P=0.0316;DBT经验前CDR 2.5/1000(95%CI:2.2,2.9),经验后3.5/1000(95%CI:3.0,4.0),P=0.0203;DBT经验前PPV2 26.9%(95%CI:19.9%,35.3%),经验后36.1%(95%CI:31.7%,40.7%),P=0.0212;DBT经验前PPV3 31.2%(95%CI:24.0%,39.3%),经验后40.0%(95%CI:35.5%,44.6%),P=0.0290。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare screening mammography recall rate, cancer detection rate (CDR), and positive predictive values (PPVs) for digital mammography before and after radiologist experience with digital breast tomosynthesis (DBT). Materials and Methods This retrospective study was approved by the institutional review board and compliant with HIPAA. The authors reviewed screening mammography audit data obtained from 2009 to 2014, during which 108 276 digital mammographic examinations were performed (50 062 before and 58 214 after experience with DBT). Recall rate, CDR, PPV of positive screening result (PPV1), PPV of biopsy recommendation (PPV2), and PPV of biopsies performed (PPV3) of digital mammography for six radiologists were compared before (2009-2011) and after (2012-2014) experience with DBT. Radiologists worked in both a community setting, in which only digital mammography was available, and in two tertiary breast imaging centers, where they interpreted DBT images starting in 2012. Data were examined by using generalized linear mixed modeling wherein observations were nested for each radiologist over time. P < .05 was considered indicative of a statistically significant difference; 95% confidence intervals (CIs) were calculated. Results The average recall rate was 6.8% (range, 3.6%-9.7%) before experience with DBT and 7.9% (range, 5.5%-9.5%) after (P = .0316). Before experience with DBT, the recall rate increased only 0.01% for each year from 2009 to 2011 (P = .9727). After experience with DBT, the recall rate increased 0.65% for each year from 2012 to 2014 (P < .0127). CDR increased from 2.5 per 1000 examinations (95% CI: 2.2, 2.9) to 3.5 per 1000 examinations (95% CI: 3.0, 4.0; P = .0203). PPV2 and PPV3 increased significantly after experience with DBT, from 26.9% (95% CI: 19.9%, 35.3%) to 36.1% (95% CI: 31.7%, 40.7%; P = .0212) for PPV2 and from 31.2% (95% CI: 24.0%, 39.3%) to 40.0% (95% CI: 35.5%, 44.6%; P = .0290) for PPV3. Conclusion Recall rate, CDR, PPV2, and PPV3 of digital mammography increased after radiologist experience with DBT. © RSNA, 2017.
引用
- DiPrete O, Lourenco AP, Baird GL, et al. Screening Digital Mammography Recall Rate: Does It Change with Digital Breast Tomosynthesis Experience? Radiology. 2017. PMID: 29173123. doi:10.1148/radiol.2017170517
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。