文献速递乳腺乳腺X线

提高数字乳腺断层摄影阅片时间:使用并行计算机辅助检测(CAD)的试点多阅片者多病例研究

Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD).
PubMed 文献 · Eur J Radiol · 2017-10-24

该回顾性交叉研究纳入6名放射科医生阅读80例数字乳腺断层摄影(DBT)病例(21名女性中23个恶性病灶),比较有无并行CAD对判读性能和阅片时间的影响。结果显示使用CAD时平均阅片时间从48.2秒降至39.1秒(降低23.5%,95%CI:7.0-37.0%),AUC非劣效(无CAD 0.854 vs 有CAD 0.850,差值95%CI:-0.046,0.039),敏感度、特异度和召回率相似。

要点

  • 并行CAD将DBT平均阅片时间从48.2秒缩短至39.1秒,降低23.5%。
  • 使用CAD时AUC为0.850,无CAD为0.854,达到非劣效。
  • 每患者敏感度有无CAD均为0.865,特异度和召回率变化小且未达统计学显著。

核心结论

  • 并行CAD使阅片时间更快,且放射科医生判读性能非劣效;有无CAD时敏感度、特异度和召回率相似。

研究设计与样本

  • 回顾性交叉研究,6名放射科医生阅读80例DBT病例(21名女性中23个恶性病灶),比较有无并行CAD;CAD系统从DBT层面检测并提取可疑肿块、结构扭曲和不对称,融合到对应合成图像形成CAD增强合成图像;采用多阅片者多病例(MRMC)方法分析所有终点,要求正确病灶定位;AUC基于0-100%恶性概率(POM)评分,敏感度和特异度基于BI-RADS评分(3分及以上为阳性)。

诊断标准与关键数值

  • 无CAD时平均AUC为0.854(范围0.785-0.891,95%CI:0.769,0.939),有CAD时为0.850(范围0.746-0.905,95%CI:0.751,0.949),差值95%CI:-0.046,0.039,达到非劣效;每患者敏感度有无CAD均为0.865(差值95%CI:-0.070,0.070);每病灶敏感度无CAD为0.790,有CAD为0.812,提高0.022(差值95%CI:-0.046,0.089);特异度差异为-0.014(差值95%CI:-0.079,0.050),非癌症病例召回率增加0.025(差值95%CI:-0.036,0.087)。

临床应用与阅片要点

  • 原文结论为并行CAD使阅片时间更快且判读性能非劣效,敏感度、特异度和召回率相似;原文未据此给出具体阅片建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time.

MATERIALS AND METHODS: The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive.

RESULTS: Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0.014 difference (95% CI for difference: -0.079,0.050) and a small 0.025 increase (95% CI for difference: -0.036,0.087) in recall rate in non-cancer cases were observed with CAD.

CONCLUSIONS: Concurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Balleyguier C, Arfi-Rouche J, Levy L, et al. Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD). Eur J Radiol. 2017. PMID: 29153373. doi:10.1016/j.ejrad.2017.10.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。