弹性超声与二维超声诊断乳腺癌腋窝淋巴结转移的比较
研究对78例疑似乳腺癌患者的78枚腋窝淋巴结行弹性超声与二维超声检查,比较两种方法及联合法诊断转移的价值。联合法敏感度93.2%,高于二维超声的77.3%(p<0.05);联合法与二维超声AUC差异有统计学意义(p<0.05)。结论认为二维超声联合弹性超声可提高对乳腺癌转移性腋窝淋巴结特征的诊断能力。
要点
- 转移性与非转移性淋巴结弹性评分分别为3.11±0.75与1.44±0.82(p<0.05)。
- 联合法敏感度93.2%,二维超声77.3%,两者差异有统计学意义(p<0.05)。
- 二维超声与联合法AUC差异有统计学意义(p<0.05)。
核心结论
- 二维超声联合弹性超声可提高对乳腺癌转移性腋窝淋巴结特征的诊断能力。
研究设计与样本
- 对78例疑似乳腺癌患者的78枚腋窝淋巴结行弹性超声与二维超声检查。
- 二维超声对形态、长短轴比、皮质厚度及淋巴结门评分并求和作为每枚淋巴结的二维超声评分。
- 弹性评分采用四点法;联合评分为二维超声评分与弹性评分之和。
- 应变比通过比较淋巴结平均应变与皮下组织平均应变计算。
关键影像表现/征象
- 转移性腋窝淋巴结弹性评分为3.11±0.75,非转移性为1.44±0.82(p<0.05)。
诊断标准与关键数值
- 二维超声敏感度77.3%、特异度76.5%、准确率76.9%。
- 弹性评分敏感度86.4%、特异度85.3%、准确率85.9%;二维超声与弹性评分各指标差异均无统计学意义(均p>0.05)。
- 联合法敏感度93.2%、特异度73.5%、准确率84.6%。
- 二维超声与联合法敏感度差异有统计学意义(p<0.05);二维超声与联合法AUC差异有统计学意义(p<0.05)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare diagnostic value of two-dimensional (2D) ultrasonography and elastosonography for suspected axillary lymph node metastasis of breast cancer.
MATERIALS AND METHODS: Elastosonography and 2D ultrasonography were performed on 78 axillary lymph nodes of 78 patients with suspected breast cancer. Scores of shape, long- to short-axis ratio, cortical thickness, and lymph node hilum were summed as the score of each lymph node at 2D ultrasonography, while a four-point scale was adopted for elasticity scoring. The combined score of each lymph node was obtained by summing the score at 2D ultrasonography and that at elasticity scoring. The strain ratio was calculated by comparison of the average strain of the lymph node with that of the subcutaneous tissue. Diagnostic efficacies of 2D ultrasonography, elasticity scoring, and the combined method were compared.
RESULTS: There were 78 axillary lymph nodes, including 34 non-metastatic and 44 metastatic nodes. The elasticity scores of non-metastatic and metastatic axillary lymph nodes were 1.44±0.82 and 3.11±0.75, respectively (p<0.05). The difference in area under the operating characteristic curve (AUC) was statistically significant between 2D ultrasonography and the combined method (p<0.05). The sensitivity, specificity, and accuracy of 2D ultrasonography and elasticity scoring were 77.3% versus 86.4%, 76.5% versus 85.3%, and 76.9% versus 85.9%, respectively (all p>0.05), and those of the combined method were 93.2%, 73.5%, and 84.6%, respectively. There was a significant difference in sensitivity between 2D ultrasonography and the combined method (p<0.05).
CONCLUSIONS: Combined application of 2D ultrasonography with elastosonography can improve the diagnostic capability for metastatic axillary lymph node characterisation in breast cancer.
引用
- Zhao QL, Xia XN, Zhang Y, et al. Elastosonography and two-dimensional ultrasonography in diagnosis of axillary lymph node metastasis in breast cancer. Clin Radiol. 2017. PMID: 29111238. doi:10.1016/j.crad.2017.09.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。