文献速递乳腺乳腺X线

挪威乳腺癌筛查项目中的乳腺压迫参数与乳腺X线摄影密度

Breast compression parameters and mammographic density in the Norwegian Breast Cancer Screening Programme.
PubMed 文献 · Eur Radiol · 2017-11-02

研究纳入挪威乳腺癌筛查项目2014—2015年14,698名接受双体位数字乳腺X线摄影的女性,分析压迫力、压迫压强和压迫后乳腺厚度与自动软件测得的绝对及百分比致密体积的关联。压迫压强与绝对致密体积呈负相关(CC ρ=-0.37,MLO ρ=-0.34),压迫后乳腺厚度与百分比致密体积呈负相关(CC ρ=-0.56,MLO ρ=-0.62),校正回归分析结果一致。作者认为乳腺压迫参数可能影响自动软件的密度估计。

要点

  • 压迫压强与绝对致密体积呈负相关(CC ρ=-0.37,MLO ρ=-0.34)
  • 压迫后乳腺厚度与百分比致密体积呈负相关(CC ρ=-0.56,MLO ρ=-0.62)
  • 乳腺压迫参数可能影响自动软件的密度估计

核心结论

  • 研究结果表明乳腺压迫参数可能影响自动软件测得的绝对及百分比致密体积。

研究设计与样本

  • 研究纳入2014—2015年挪威乳腺癌筛查项目中14,698名接受双体位(CC和MLO)数字乳腺X线摄影的女性,获取乳腺压迫参数、乳腺体积、绝对及百分比致密体积和体重指数数据,采用Spearman相关系数衡量相关性,并用线性回归分析关联,校正乳腺体积、年龄和BMI。

诊断标准与关键数值

  • 压迫压强与绝对致密体积呈负相关:CC ρ=-0.37,MLO ρ=-0.34
  • 压迫后乳腺厚度与百分比致密体积呈负相关:CC ρ=-0.56,MLO ρ=-0.62

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate possible associations between breast compression parameters, including compression force, pressure and compressed breast thickness, and mammographic density assessed by an automated software.

METHODS: We obtained data on breast compression parameters, breast volume, absolute and percentage dense volume, and body mass index for 14,698 women screened with two-view (craniocaudal, CC, and mediolateral oblique, MLO) digital mammography, in the Norwegian Breast Cancer Screening Programme, 2014-2015. The Spearman correlation coefficient (ρ) was used to measure correlation between breast compression parameters, breast volume and absolute and percentage dense volume. Linear regression was used to examine associations between breast compression parameters and absolute and percentage dense volume, adjusting for breast volume, age and BMI.

RESULTS: A fair negative correlation was observed between compression pressure and absolute dense volume (ρ = - 0.37 for CC and ρ = - 0.34 for MLO). A moderate negative correlation was identified for compressed breast thickness and percentage dense volume (ρ = - 0.56 for CC and ρ = - 0.62 for MLO). These correlations were corroborated by the corresponding associations obtained in the adjusted regression analyses.

CONCLUSIONS: Results from this study indicate that breast compression parameters may influence absolute and percentage dense volume measured by the automated software.

KEY POINTS: • A fair correlation was identified between compression pressure and absolute dense volume • A moderate correlation was identified between compressed breast thickness and percentage dense volume • Breast compression may influence automated density estimates.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Moshina N, Roman M, Waade GG, et al. Breast compression parameters and mammographic density in the Norwegian Breast Cancer Screening Programme. Eur Radiol. 2017. PMID: 29098437. doi:10.1007/s00330-017-5104-5