小乳腺癌超声表现与腋窝淋巴结转移的相关性
研究分析了143例乳腺癌患者共153个小乳腺癌(最大径≤2.0 cm)的术前超声图像,其中47个肿瘤伴腋窝淋巴结转移。单因素和多因素分析显示,穿支血管和淋巴结最大皮质厚度>3.0 mm与小乳腺癌腋窝淋巴结转移相关(多因素OR分别为48.783和46.754,p<0.05)。
要点
- 小乳腺癌中,超声发现穿支血管和淋巴结最大皮质厚度>3.0 mm与腋窝淋巴结转移相关。
- 多因素分析中,穿支血管的OR=48.783,淋巴结最大皮质厚度>3.0 mm的OR=46.754(p<0.05)。
- 单因素分析中,穿支血管χ2=13.945,淋巴结最大皮质厚度χ2=51.276(p<0.05)。
核心结论
- 在小乳腺癌中,超声征象穿支血管和淋巴结最大皮质厚度>3.0 mm与腋窝淋巴结转移相关,多因素OR分别为48.783和46.754(p<0.05)。
研究设计与样本
- 研究分析了143例乳腺癌患者共153个小乳腺癌(最大径≤2.0 cm)的术前超声图像,47个肿瘤伴腋窝淋巴结转移;所有患者经腋窝根治性手术或前哨淋巴结活检确诊;采用卡方检验进行单因素分析,逻辑回归进行多因素分析,以病理诊断淋巴结转移为因变量、各超声征象为自变量建立模型。
关键影像表现/征象
- 超声征象包括形态不规则、微小分叶轮廓、毛刺、微钙化、后方回声衰减、血流分级、穿支血管、筋膜或Cooper韧带改变以及淋巴结最大皮质厚度。
诊断标准与关键数值
- 穿支血管与腋窝淋巴结转移相关:单因素分析χ2=13.945(p<0.05),多因素分析OR=48.783(p<0.05)。
- 淋巴结最大皮质厚度>3.0 mm与腋窝淋巴结转移相关:单因素分析χ2=51.276(p<0.05),多因素分析OR=46.754(p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
To study the correlation of ultrasonographic signs of small breast cancer (maximum diameter ≤2.0 cm) with axillary lymph node metastasis, pre-operative ultrasonographic images of 153 small breast malignant neoplasms in 143 breast cancer patients were analyzed according to their pathologic features. Of the small breast tumors included, 47 showed axillary lymph node metastasis. Diagnosis of all patients was obtained with radical axillary surgery or a sentinel lymph node biopsy procedure. Ultrasonographic signs included irregular shape, microlobulated contour, spiculation, microcalcification, posterior echo attenuation, blood-flow grade, perforating vessels, changes in fascia or cooper's ligament and maximum cortical thickness of lymph nodes. The relationship between ultrasonographic features and axillary lymph node metastasis was analyzed using a chi-square test for univariate distributions and logistic regression for multivariate analysis. A logistic regression model was established by taking the pathologic diagnosis of lymph node metastasis as the dependent variable and the ultrasonographic signs of each small breast cancer as independent variables. In small breast cancer, characteristics such as perforating vessels and maximum cortical thickness of lymph nodes >3.0 mm correlated well with axillary lymph node metastasis as determined by univariate analysis (χ2 = 13.945, 51.276, respectively, p <0.05) and multivariate analysis (OR = 48.783, 46.754, respectively, p <0.05).
引用
- Yu X, Hao X, Wan J, et al. Correlation between Ultrasound Appearance of Small Breast Cancer and Axillary Lymph Node Metastasis. Ultrasound Med Biol. 2017. PMID: 29150365. doi:10.1016/j.ultrasmedbio.2017.09.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。