文献速递妇产影像腹部USMR

经阴道超声与磁共振成像诊断深部浸润型子宫内膜异位症的系统评价与Meta分析

Transvaginal ultrasound vs magnetic resonance imaging for diagnosing deep infiltrating endometriosis: systematic review and meta-analysis.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-01-01

该系统评价纳入6项研究共424例患者,比较经阴道超声与磁共振成像诊断深部浸润型子宫内膜异位症的准确性。两种技术在直肠乙状结肠、直肠阴道隔和子宫骶韧带部位的诊断性能相似,但合并敏感度、特异度和诊断比值比的置信区间均较宽,异质性中等或较高。

要点

  • 经阴道超声与磁共振成像诊断深部浸润型子宫内膜异位症的准确性相似。
  • 直肠乙状结肠部位两种技术合并敏感度均为0.85,特异度分别为0.96和0.95。
  • 直肠阴道隔和子宫骶韧带部位合并敏感度较低,置信区间较宽。

核心结论

  • 经阴道超声与磁共振成像检测累及直肠乙状结肠、子宫骶韧带和直肠阴道隔的深部浸润型子宫内膜异位症的诊断性能相似。

研究设计与样本

  • 系统评价与Meta分析,纳入6项研究共424例患者,均为同一组患者接受经阴道超声和磁共振成像检查,以手术数据为参考标准,质量评估采用QUADAS-2工具,使用随机效应模型。

诊断标准与关键数值

  • 磁共振成像检测直肠乙状结肠深部浸润型子宫内膜异位症:合并敏感度0.85(95%CI 0.78-0.90),特异度0.95(95%CI 0.83-0.99),阳性似然比18.4(95%CI 4.7-72.4),阴性似然比0.16(95%CI 0.11-0.24),诊断比值比116(95%CI 23-585)。
  • 经阴道超声检测直肠乙状结肠深部浸润型子宫内膜异位症:合并敏感度0.85(95%CI 0.68-0.94),特异度0.96(95%CI 0.85-0.99),阳性似然比20.4(95%CI 4.7-88.5),阴性似然比0.16(95%CI 0.07-0.38),诊断比值比127(95%CI 14-1126)。
  • 磁共振成像检测直肠阴道隔深部浸润型子宫内膜异位症:合并敏感度0.66(95%CI 0.51-0.79),特异度0.97(95%CI 0.89-0.99),阳性似然比22.5(95%CI 6.7-76.2),阴性似然比0.38(95%CI 0.23-0.52),诊断比值比65(95%CI 21-204)。
  • 经阴道超声检测直肠阴道隔深部浸润型子宫内膜异位症:合并敏感度0.59(95%CI 0.26-0.86),特异度0.97(95%CI 0.94-0.99),阳性似然比23.5(95%CI 9.1-60.5),阴性似然比0.42(95%CI 0.18-0.97),诊断比值比56(95%CI 11-275)。
  • 磁共振成像检测子宫骶韧带深部浸润型子宫内膜异位症:合并敏感度0.70(95%CI 0.55-0.82),特异度0.93(95%CI 0.87-0.97),阳性似然比10.4(95%CI 5.1-21.2),阴性似然比0.32(95%CI 0.20-0.51),诊断比值比32(95%CI 12-85);经阴道超声检测子宫骶韧带深部浸润型子宫内膜异位症:合并敏感度0.67(95%CI 0.55-0.77),特异度0.86(95%CI 0.73-0.93),阳性似然比4.8(95%CI 2.6-9.0),阴性似然比0.38(95%CI 0.29-0.50),诊断比值比12(95%CI 7-24)。

局限性

  • 两种技术在所有评估部位的合并敏感度、特异度和诊断比值比的置信区间均较宽。
  • 在大多数评估部位,经阴道超声和磁共振成像的敏感度和特异度异质性为中等或较高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To perform a systematic review of studies comparing the accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) in diagnosing deep infiltrating endometriosis (DIE) including only studies in which patients underwent both techniques.

METHODS: An extensive search was carried out in PubMed/MEDLINE and Web of Science for papers from January 1989 to October 2016 comparing TVS and MRI in DIE. Studies were considered eligible for inclusion if they reported on the use of TVS and MRI in the same set of patients for the preoperative detection of endometriosis in pelvic locations in women with clinical suspicion of DIE and using surgical data as a reference standard. Quality was assessed using the QUADAS-2 tool. A random-effects model was used to determine pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratio (DOR).

RESULTS: Of 375 citations identified, six studies (n = 424) were considered eligible. For MRI in the detection of DIE in the rectosigmoid, pooled sensitivity was 0.85 (95% CI, 0.78-0.90), specificity was 0.95 (95% CI, 0.83-0.99), LR+ was 18.4 (95% CI, 4.7-72.4), LR- was 0.16 (95% CI, 0.11-0.24) and DOR was 116 (95% CI, 23-585). For TVS in the detection of DIE in the rectosigmoid, pooled sensitivity was 0.85 (95% CI, 0.68-0.94), specificity was 0.96 (95% CI, 0.85-0.99), LR+ was 20.4 (95% CI, 4.7-88.5), LR- was 0.16 (95% CI, 0.07-0.38) and DOR was 127 (95% CI, 14-1126). For MRI in the detection of DIE in the rectovaginal septum, pooled sensitivity was 0.66 (95% CI, 0.51-0.79), specificity was 0.97 (95% CI, 0.89-0.99), LR+ was 22.5 (95% CI, 6.7-76.2), LR- was 0.38 (95% CI, 0.23-0.52) and DOR was 65 (95% CI, 21-204). For TVS in the detection of DIE in the rectovaginal septum, pooled sensitivity was 0.59 (95% CI, 0.26-0.86), specificity was 0.97 (95% CI, 0.94-0.99), LR+ was 23.5 (95% CI, 9.1-60.5), LR- was 0.42 (95% CI, 0.18-0.97) and DOR was 56 (95% CI, 11-275). For MRI in the detection of DIE in the uterosacral ligaments, pooled sensitivity was 0.70 (95% CI, 0.55-0.82), specificity was 0.93 (95% CI, 0.87-0.97), LR+ was 10.4 (95% CI, 5.1-21.2), LR- was 0.32 (95% CI, 0.20-0.51) and DOR was 32 (95% CI, 12-85). For TVS in the detection of DIE in the uterosacral ligaments, pooled sensitivity was 0.67 (95% CI, 0.55-0.77), specificity was 0.86 (95% CI, 0.73-0.93), LR+ was 4.8 (95% CI, 2.6-9.0), LR- was 0.38 (95% CI, 0.29-0.50) and DOR was 12 (95% CI, 7-24). Confidence intervals of pooled sensitivities, specificities and DOR were wide for both techniques in all the locations considered. Heterogeneity was moderate or high for sensitivity and specificity for both TVS and MRI in most locations assessed. According to QUADAS-2, the quality of the included studies was considered good for most domains.

CONCLUSION: The diagnostic performance of TVS and MRI is similar for detecting DIE involving rectosigmoid, uterosacral ligaments and rectovaginal septum. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Guerriero S, Saba L, Pascual MA, et al. Transvaginal ultrasound vs magnetic resonance imaging for diagnosing deep infiltrating endometriosis: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2018. PMID: 29154402. doi:10.1002/uog.18961

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。