含铁与不含铁基准标记线性置入用于前列腺放疗的MRI可视化比较
该研究纳入27例行CT/MRI融合调强放疗的前列腺癌患者,比较含铁Gold Anchor™(GA)与不含铁VISICOIL™(VIS)基准标记的影像可视化质量。结果显示计划CT上两者伪影评分相似,但MRI上前列腺GM可视化GA优于VIS。作者认为含铁金标记有助于CT和MRI配准,尤其适用于立体定向体部放疗和调强放疗等高精度放疗。
要点
- 计划CT上GA与VIS的伪影可视化评分相似。
- MRI上前列腺GM可视化GA优于VIS。
- GA线性形状可见度评分为3.4-4.1分,而VIS为5分(1分最差,5分最佳)。
核心结论
- 计划CT上GA(含铁标记)与VIS(不含铁标记)可视化质量相似,但MRI上GA优于VIS;含铁金标记有助于CT和MRI配准,尤其适用于立体定向体部放疗和调强放疗等高精度放疗。
研究设计与样本
- 27例患者接受CT/MRI融合调强放疗;由泌尿科医生置入标记,前列腺一侧线性置入含铁Gold Anchor™(GA)标记(直径0.28 mm,长10 mm,22 G针),对侧线性置入不含铁VISICOIL™(VIS)标记(直径0.35 mm,长10 mm,19 G针);MRI多采用T2*加权成像;由两名放射肿瘤科医生和一名放射技师评估并赋可视化质量评分(GA形状、CT伪影、MRI信号空洞)。
关键影像表现/征象
- 计划CT上GA与VIS的伪影可视化平均评分相似。
- MRI上前列腺GM可视化GA优于VIS。
- GA线性形状可见度为3.4-4.1分,而VIS为5分(1分最差,5分最佳)。
临床应用与阅片要点
- 作者认为含铁金标记有助于CT和MRI配准,尤其适用于立体定向体部放疗和调强放疗等高精度放疗。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Visualizing the gold marker (GM) in CT and MRI is critical, especially for registration in high-precision radiotherapy. GM sizes vary. Large markers are easily visualized in MRI. Small GMs show fewer artefacts in CT but are harder to detect in MRI because the signal is influenced by metal in MRI. Therefore, we compared MRI visualization between linearly placed new iron-containing marker and non-iron containing marker.
METHODS: 27 patients underwent CT/MRI fusion-based intensity-modulated radiotherapy. The gold markers were placed by urologists. An iron-containing Gold Anchor™ (GA) marker (diameter, 0.28 mm; length, 10 mm) was placed by using a 22 G needle on one side of the prostate linearly. A non-iron-containing VISICOIL™ (VIS) marker (diameter, 0.35 mm; length, 10 mm) was placed by using a 19 G needle on the opposite side linearly. T2* weighted MRI was mostly performed. Two Radiation Oncologists and one Radiation Technologist evaluated and assigned visual quality scores (GA shape, CT artefacts, MRI signal voids).
RESULTS: The mean visualization scores of artefacts were similar between GA and VIS in planning CT. GM visualization in MRI of the prostate was better for GA than for VIS. The visibility of the linear shape of the GA was 3.4-4.1 points when the VIS was 5 points (1 is worst and 5 is best).
CONCLUSION: Visualization quality was similar between GA (iron-containing marker) and VIS (non-iron-containing marker) in planning CT, but was better for GA than for VIS in MRI. To achieve high-precision radiotherapy, an iron-containing gold marker was useful for CT and MRI registration. Advances in knowledge: An iron-containing fiducial marker was useful for CT and MRI registration, especially in high-precision radiotherapy, such as stereotactic body radiotherapy and intensity-modulated radiotherapy.
引用
- Tanaka O, Komeda H, Tamaki M, et al. Comparison of MRI visualization between linearly placed iron-containing and non-iron-containing fiducial markers for prostate radiotherapy. Br J Radiol. 2017. PMID: 29120662. doi:10.1259/bjr.20170612
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。