前列腺扩散加权成像:是否应使用定量指标以更好地表征起源于外周带的局灶性病变?
本研究比较定性DW-MRI PI-RADSv2.0评分与定量DW-MRI参数对外周带前列腺癌的诊断一致性及准确性,纳入74例患者共92个外周带病灶,由两名放射科医师独立评分并测量ADCmean及九项ADC衍生参数。结果显示定性评估的读者间一致性仅为中等,而定量评估一致性极好;全前列腺ADCratio是唯一与恶性显著相关的独立变量,在截断值0.68时两名读者敏感度分别为94%和90%,特异度分别为60%和38%。
要点
- 定性DW PI-RADSv2.0评分对外周带病灶的读者间一致性仅为中等(fair)。
- 标准化ADCmean及衍生定量参数使读者间一致性达到极好(excellent)。
- 全前列腺ADCratio在截断值0.68时敏感度为94%–90%,优于镜像外周带ADCratio。
核心结论
- 全前列腺ADCratio改善了定性评估的读者间一致性及对外周带局灶性病变的表征。
研究设计与样本
- 研究纳入74例患者(年龄64.3±5.6岁;PSA中位数8 ng/ml;70例直肠指检正常)共92个外周带病灶,两名放射科医师独立赋值DW-MRI-PIRADS评分,并测量标准化ADCmean及九项ADC衍生参数(含全前列腺ADCratio与镜像外周带ADCratio);肿瘤以手术组织学为参考标准,良性病灶以MRI-TRUS融合穿刺活检为参考标准;读者间一致性采用Cohen-kappa系数与组内相关系数(ICC)评估,单因素及多因素回归确定最具预测价值的因素。
诊断标准与关键数值
- 全前列腺ADCratio在截断值0.68时,读者1敏感度94%、特异度60%,读者2敏感度90%、特异度38%;单因素分析中ADCmean、全前列腺ADCratio与WL-ADCmean表现相当,且均显著优于镜像ADCratio(p<0.001);多因素分析中仅全前列腺ADCratio与恶性显著独立相关。
临床应用与阅片要点
- 作者认为全前列腺ADCratio可能规避不同中心间ADC指标的变异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare inter-reader concordance and accuracy of qualitative diffusion-weighted (DW) PIRADSv2.0 score with those of quantitative DW-MRI for the diagnosis of peripheral zone prostate cancer.
MATERIALS AND METHODS: Two radiologists independently assigned a DW-MRI-PIRADS score to 92 PZ-foci, in 74 patients (64.3±5.6 years old; median PSA level: 8 ng/ml, normal DRE in 70 men). A standardised ADCmean and nine ADC-derived parameters were measured, including ADCratios with the whole-prostate (WP-ADCratio) or the mirror-PZ (mirror-ADCratio) as reference areas. Surgical histology and MRI-TRUS fusion-biopsy were the reference for tumours and benign foci, respectively. Inter-reader agreement was assessed by the Cohen-kappa-coefficient and the intraclass correlation coefficient (ICC). Univariate-multivariate regressions determined the most predictive factor for cancer.
RESULTS: Fifty lesions were malignant. Inter-reader concordance was fair for qualitative assessment, but excellent for quantitative assessment for all quantitative variables. At univariate analysis, ADCmean, WP-ADCratio and WL-ADCmean performed equally, but significantly better than the mirror-ADCratio (p<0.001). At multivariate analysis, the only independent variable significantly associated with malignancy was the whole-prostate-ADCratio. At a cut-off value of 0.68, sensitivity was 94-90 % and specificity was 60-38 % for readers 1 and 2, respectively.
CONCLUSION: The whole-prostate-ADCratio improved the qualitative inter-reader concordance and characterisation of focal PZ-lesions.
KEY POINTS: • Inter-reader concordance of DW PI-RADSv2.0 score for PZ lesions was only fair. • Using a standardised ADCmean measurement and derived DW-quantitative parameters, concordance was excellent. • The whole-prostate ADCratio performed significantly better than the mirror-ADCratio for cancer detection. • At a cut-off of 0.68, sensitivity values of WP-ADCratio were 94-90 %. • The whole-prostate ADCratio may circumvent variations of ADC metrics across centres.
引用
- Pierre T, Cornud F, Colléter L, et al. Diffusion-weighted imaging of the prostate: should we use quantitative metrics to better characterize focal lesions originating in the peripheral zone? Eur Radiol. 2017. PMID: 29168004. doi:10.1007/s00330-017-5107-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。