影像机构对前列腺MRI检查中PI-RADS v2最低技术标准的依从性
本研究评估107家影像机构在PI-RADS v2发布后行前列腺MRI时对21项最低技术标准的依从性,发现T2WI频率分辨率和DCE时间分辨率依从性最差,3T在部分参数上优于1.5T,教学机构在T2WI层厚和DCE时间分辨率上依从性更高,作者认为标准需加强教育且部分可能过严。
要点
- T2WI频率分辨率≤0.4 mm依从率仅16.8%,DCE时间分辨率<10 s仅31.5%,为最薄弱环节。
- 3T在T2WI相位分辨率和DWI层间隔的依从性高于1.5T(P < .05)。
- 有无直肠内线圈的各参数依从性无差异(P > .05),2016年与2015年各参数依从性无改善(P > .05)。
核心结论
- 影像机构对PI-RADS v2最低技术标准的依从性参差不齐,T2WI频率分辨率和DCE时间分辨率尤其差;标准需更广泛的社区教育,部分技术标准可能过严,应考虑修订。
研究设计与样本
- 回顾性纳入107家独特影像机构在PI-RADS v2发布后施行的107例前列腺MRI,转诊至三级医疗中心行二次判读,复习图像集、DICOM头信息和外院报告以评估对21项选定最低技术标准的依从性。
关键影像表现/征象
- 硬件配置:23.1%为1.5T无直肠内线圈,7.7%为1.5T有直肠内线圈,63.5%为3T无直肠内线圈,5.8%为3T有直肠内线圈。
- 高b值(≥1400 s/mm²)图像纳入率为58.0%,其中可计算者占25.9%。
诊断标准与关键数值
- T2WI频率分辨率≤0.4 mm依从率16.8%,相位分辨率≤0.7 mm依从率48.6%。
- DWI视野(FOV)120–220 mm依从率30.0%。
- DCE层厚3 mm依从率33.3%,时间分辨率<10 s依从率31.5%。
- 3T在T2WI相位分辨率和DWI层间隔的依从性高于1.5T(P < .05)。
- 教学机构在T2WI层厚和DCE时间分辨率的依从性更高(P < .05)。
临床应用与阅片要点
- 阅片和报告时可参考本研究列出的PI-RADS v2最低技术标准依从率,识别外院前列腺MRI在T2WI频率分辨率和DCE时间分辨率上的常见不足。
- 作者认为标准需更广泛的社区教育,部分技术标准可能过严并应考虑修订。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study aimed to assess variability in imaging facilities' adherence to the minimum technical standards for prostate magnetic resonance imaging acquisition established by Prostate Imaging-Reporting and Data System (PI-RADS) version 2 (v2).
METHODS: A total of 107 prostate magnetic resonance imaging examinations performed at 107 unique imaging facilities after the release of PI-RADS v2 and that were referred to a tertiary care center for secondary interpretation were included. Image sets, DICOM headers, and outside reports were reviewed to assess adherence to 21 selected PI-RADS v2 minimum technical standards.
RESULTS: Hardware arrangements were 23.1%, 1.5T without endorectal coil; 7.7%, 1.5T with endorectal coil; 63.5%, 3T without endorectal coil; and 5.8%, 3T with endorectal coil. Adherence to minimum standards was lowest on T2 weighted imaging (T2WI) for frequency resolution ≤0.4 mm (16.8%) and phase resolution ≤0.7 mm (48.6%), lowest on diffusion-weighted imaging (DWI) for field of view (FOV) 120-220 mm (30.0%), and lowest on dynamic contrast-enhanced (DCE) imaging for slice thickness 3 mm (33.3%) and temporal resolution <10 s (31.5%). High b-value (≥1400 s/mm2) images were included in 58.0% (calculated in 25.9%). Adherence to T2WI phase resolution and DWI inter-slice gap were greater (P < .05) at 3T than at 1.5T. Adherence did not differ (P > .05) for any parameter between examinations performed with and without an endorectal coil. Adherence was greater for examinations performed at teaching facilities for T2WI slice thickness and DCE temporal resolution (P < .05). Adherence was not better for examinations performed in 2016 than in 2015 for any parameter (P > .05).
CONCLUSION: Facilities' adherence to PI-RADS v2 minimum technical standards was variable, being particularly poor for T2WI frequency resolution and DCE temporal resolution. The standards warrant greater community education. Certain technical standards may be too stringent, and revisions should be considered.
引用
- Esses SJ, Taneja SS, Rosenkrantz AB, et al. Imaging Facilities' Adherence to PI-RADS v2 Minimum Technical Standards for the Performance of Prostate MRI. Acad Radiol. 2017. PMID: 29107458. doi:10.1016/j.acra.2017.08.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。