文献速递技术与安全PETCT

贝叶斯惩罚似然PET重建与有序子集期望最大化重建在广泛患者体重范围内对临床图像质量的影响比较

Effect of a Bayesian Penalized Likelihood PET Reconstruction Compared With Ordered Subset Expectation Maximization on Clinical Image Quality Over a Wide Range of Patient Weights.
PubMed 文献 · AJR Am J Roentgenol · 2017-11-01

研究回顾性比较同一PET采集数据经贝叶斯惩罚似然(BPL)与有序子集期望最大化(OSEM)重建后,在41-196 kg、n=108患者中肝脏信噪比(SNR)和视觉图像质量的差异。BPL的肝脏SNR随体重和BMI增加无显著变化(p>0.05),而OSEM噪声随体重和BMI增加而增加;BPL的肝脏SNR在所有BMI组均显著高于标准OSEM(p<0.0002)。视觉图像质量在OSEM图像中随体重和BMI增加下降更快;BPL提供更一致的视觉图像质量和肝脏背景SNR,对最重患者获益最大。

要点

  • BPL重建的肝脏SNR在所有BMI组均显著高于OSEM(p<0.0002)。
  • 随体重和BMI增加,OSEM噪声增加而BPL肝脏SNR无显著变化(p>0.05)。
  • 视觉图像质量在OSEM图像中随体重和BMI增加下降更快,BPL更一致。

核心结论

  • BPL较OSEM提供更一致的视觉评估图像质量和肝脏背景SNR,对最重患者获益最大。

研究设计与样本

  • 回顾性研究,同一PET采集数据分别经BPL和标准OSEM重建,患者体重范围41-196 kg,n=108,静脉注射18F-FDG 4 MBq/kg。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: A study was performed to compare background liver signal-to-noise ratio (SNR) and visually assessed image quality of clinical PET/CT studies from the same PET acquisition data reconstructed by Bayesian penalized likelihood (BPL) and ordered subset expectation maximization (OSEM) over a range of patient weights.

MATERIALS AND METHODS: The effect of a BPL PET reconstruction algorithm on liver SNR and visually assessed image quality over a range of patient weights (41-196 kg; n = 108) was retrospectively compared with standard-of-care OSEM reconstruction on the same PET acquisition data after IV administration of 18F-FDG (4 MBq/kg).

RESULTS: BPL showed no significant change (p > 0.05) in liver SNR with increasing weight and body mass index (BMI), whereas OSEM showed increasing noise with increasing weight and BMI. The liver SNR was significantly higher using BPL than a standard OSEM reconstruction (p < 0.0002 for all BMI groups). Visually assessed image quality declined at a greater rate with increasing weight and BMI in the OSEM images than with BPL images.

CONCLUSION: BPL provides a more consistent visually assessed image quality and liver background SNR than does OSEM, with the greatest benefit for the heaviest patients.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Chilcott AK, Bradley KM, McGowan DR, et al. Effect of a Bayesian Penalized Likelihood PET Reconstruction Compared With Ordered Subset Expectation Maximization on Clinical Image Quality Over a Wide Range of Patient Weights. AJR Am J Roentgenol. 2017. PMID: 29091008. doi:10.2214/AJR.17.18060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。