文献速递腹部技术与安全US

新型点剪切波弹性成像技术评估慢性肝病患者肝脏硬度的前瞻性验证:观察者内与观察者间可重复性研究

Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease.
PubMed 文献 · Korean J Radiol · 2017-09-21

这项前瞻性研究纳入33例慢性肝病患者,在同一时段内用VTQ和S-Shearwave测量肝脏硬度,并在8小时间隔后重复两次S-Shearwave检查以评估观察者内和观察者间变异。结果显示,S-Shearwave的观察者内和观察者间一致性均极佳(ICC分别为0.99和0.98),其诊断效能与VTQ相当(F≥3的AUROC:VTQ 0.89 vs S-Shearwave 0.84,p>0.48;F=4的AUROC:VTQ 0.87 vs S-Shearwave 0.94,p>0.48)。

要点

  • S-Shearwave的观察者内和观察者间一致性均极佳(ICC分别为0.99和0.98)。
  • S-Shearwave与VTQ的技术成功率无显著差异(96.9% vs 100%,p=0.63)。
  • S-Shearwave诊断F≥3和F=4的AUROC分别为0.84和0.94,与VTQ相当(p>0.48)。

核心结论

  • S-Shearwave在评估肝脏硬度方面具有极佳的观察者内和观察者间一致性,其诊断效能与VTQ相当。

研究设计与样本

  • 经机构审查委员会批准的前瞻性研究,纳入33例慢性肝病患者,在同一时段内用VTQ(Acuson S2000,Siemens)和S-Shearwave(RS-80A,Samsung Medison)测量肝脏硬度,并在8小时间隔后重复两次S-Shearwave检查以评估观察者间和观察者内变异;以瞬时弹性成像的肝脏硬度值作为参考标准。

诊断标准与关键数值

  • S-Shearwave诊断F≥3的AUROC为0.84(95%CI 0.67-0.94),诊断F=4的AUROC为0.94(95%CI 0.80-0.99);VTQ诊断F≥3的AUROC为0.89(95%CI 0.74-0.97),诊断F=4的AUROC为0.87(95%CI 0.70-0.96);两者AUROC比较p>0.48;S-Shearwave与VTQ的Obuchowski measure分别为0.94和0.95。

临床应用与阅片要点

  • S-Shearwave的观察者内和观察者间一致性均极佳(ICC分别为0.99和0.98),可用于评估慢性肝病患者的肝脏硬度。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ).

MATERIALS AND METHODS: Thirty-three patients were enrolled in this Institutional Review Board-approved prospective study. LS values were measured by VTQ on an Acuson S2000 system (Siemens Healthineer) and S-Shearwave on an RS-80A (Samsung Medison) in the same session, followed by two further S-Shearwave sessions for inter- and intra-observer variation at 8-hour intervals. The technical success rate (SR) and reliability of the measurements of both pSWE techniques were compared. The intra- and inter-observer reproducibility of S-Shearwave was determined by intraclass correlation coefficients (ICCs). LS values were measured by both methods of pSWE. The diagnostic performance in severe fibrosis (F ≥ 3) and cirrhosis (F = 4) was evaluated using the receiver operating characteristics curve analysis and the Obuchowski measure with the LS values of transient elastography as the referenced standard.

RESULTS: The VTQ (100%, 33/33) and S-Shearwave (96.9%, 32/33) techniques did not display a significant difference in technical SR (p = 0.63) or reliability of LS measurements (96.9%, 32/33; 93.9%, 30/32, respectively, p = 0.61). The inter- and intra-observer agreement for LS measurements using the S-Shearwave technique was excellent (ICC = 0.98 and 0.99, respectively). The mean LS values of both pSWE techniques were not significantly different and exhibited a good correlation (r = 0.78). To detect F ≥ 3 and F = 4, VTQ and S-Shearwave showed comparable diagnostic accuracy as indicated by the following outcomes: areas under receiver operating characteristics curve (AUROC) = 0.87 (95% confidence intervals [CI] 0.70-0.96), 0.89 for VTQ (95% CI 0.74-0.97), respectively; and AUROC = 0.84 (95% CI 0.67-0.94), 0.94 (95% CI 0.80-0.99) for S-Shearwave (p > 0.48), respectively. The Obuchowski measures were similarly high for S-Shearwave and VTQ (0.94 vs. 0.95).

CONCLUSION: S-Shearwave shows excellent inter- and intra-observer agreement and diagnostic effectiveness comparable to VTQ in detecting LS.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Ahn SJ, Lee JM, Chang W, et al. Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease. Korean J Radiol. 2017. PMID: 29089825. doi:10.3348/kjr.2017.18.6.926

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。