快速kV切换双能CT在评估胰腺腺癌术后局部复发中的作用
回顾性分析51例胰腺腺癌手术切除后随访患者,采用快速kV切换单源双能CT,比较65 keV与65 keV联合物质特异性碘图对局部复发的诊断效能。联合碘图提高了特异性(80%和56%)和阅片信心,非复发组织 normalized iodine concentration 显著更低(0.28 vs 0.35,p<0.05),而CT值无显著差异(0.63 vs 0.70,p>0.05)。
要点
- 物质特异性碘图可提高鉴别术后改变与局部复发的特异性。
- 非复发组织 normalized iodine concentration 显著低于复发组织(0.28 vs 0.35)。
- 65 keV 上CT值在非复发与复发组织间无显著差异。
核心结论
- 在术后胰腺腺癌复杂病例中,快速kV切换双能CT的物质特异性碘图可作为常规扫描的有用辅助手段来表征局部软组织。
研究设计与样本
- 经IRB批准、符合HIPPA的回顾性研究,纳入51例胰腺腺癌手术切除后随访患者,使用快速kV切换单源双能CT(Discovery CT 750HD,GE Healthcare),参考标准为随访影像、CEA和CA 19-9动态变化或活检。
关键影像表现/征象
- 非复发组织 normalized iodine concentration 为0.28,复发组织为0.35(p<0.05)。
- 非复发组织65 keV CT值为0.63,复发组织为0.70(p>0.05),无显著差异。
诊断标准与关键数值
- 联合物质特异性碘图后,两位阅片者特异性分别为80%和56%,高于单独65 keV。
- 非复发组织 normalized iodine concentration 0.28 vs 复发组织0.35(p<0.05)。
- 65 keV CT值非复发组织0.63 vs 复发组织0.70(p>0.05)。
临床应用与阅片要点
- 在胰腺腺癌术后随访中,可结合物质特异性碘图辅助鉴别局部软组织是否复发。
- normalized iodine concentration 测量有助于区分非复发与复发组织。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study is to evaluate the performance of material-specific iodine (MS-I) images generated by rapid kV-switching single-source dual-energy computed tomography (rsDECT) for distinguishing post-operative changes from local tumor recurrence in patients on follow-up for pancreatic adenocarcinoma after surgical resection.
METHODS: In this IRB-approved HIPPA-compliant study, retrospective review of 51 patients who underwent surgical resection of pancreatic adenocarcinoma was conducted and were followed up using contrast-enhanced rsDECT (Discovery CT 750HD, GE Healthcare, Milwaukee, WI). Independent qualitative assessment for presence of local tumor recurrence was performed by two radiologists who evaluated 65 keV (single-energy CT-equivalent interpretation) and 65 keV with MS-I (rsDECT interpretation) in separate sessions. Quantitative analysis of Hounsfield unit (HU, on 65 keV) and normalized iodine concentration (NIC on MS-I images; iodine concentration ratio in post-operative tissue to aorta) was measured. Follow-up imaging, temporal change of CEA and CA 19-9 or biopsy served as reference standard for presence and absence of local recurrence. Sensitivity and specificity of readers and quantitative parameters was calculated and receiver operating characteristic curves and Fisher's exact test were generated. A p value < 0.05 was considered statistically significant.
RESULTS: A total of 51 patients (27 females, 24 males) with mean age of 64 years built the final cohort. Local recurrence was absent in 23 (Group A) and present in 28 (Group B) patients. The follow-up imaging was performed within 7 months of rsDECT. For both readers, the addition of MS-I increased the specificity for tissue characterization and improved reader confidence as compared to 65 keV (specificity: 80% and 56%, respectively) images alone. Quantitative analysis revealed a significantly lower NIC (0.28 vs. 0.35; p < 0.05) for non-recurrent tissue. However, HU was not significantly different for non-recurrent and recurrent tissue (0.63 vs. 0.70; p > 0.05).
CONCLUSION: In inherently complex cases of post-operative pancreatic adenocarcinoma, MS-I images from rsDECT can be a useful adjunct to conventional scans in characterizing loco-regional soft tissue.
引用
- Parakh A, Patino M, Muenzel D, et al. Role of rapid kV-switching dual-energy CT in assessment of post-surgical local recurrence of pancreatic adenocarcinoma. Abdom Radiol (NY). 2018. PMID: 29138890. doi:10.1007/s00261-017-1390-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。