文献速递腹部技术与安全CT

胰腺癌放射治疗中胃肠道气柱的剂量学影响

Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.
PubMed 文献 · Br J Radiol · 2017-12-22

回顾性选择9例连续胰腺癌患者,利用每周锥形束CT评估胃肠道气柱变化,并与4DCT比较行非共面IMRT的剂量计算。腹部气柱变化幅度达±80%,但靶区剂量平均偏差仅-3.3%、最大-5.5%,前后径变化仅2.8%;作者认为IMRT中气柱对靶区覆盖影响极小,可能优于3DCRT。

要点

  • 每周CBCT与4DCT间腹部气柱变化幅度可达±80%。
  • 气柱变化对应靶区剂量平均偏差-3.3%、最大-5.5%。
  • 前后径变化仅2.8%,气柱变化与靶区大范围剂量变化不相关。

核心结论

  • CBCT显示胃肠道结构内气柱较大,但对IMRT靶区覆盖影响极小;由于IMRT分割照射的优势,该技术可能优于3DCRT用于治疗每日气柱影响显著的上消化道恶性肿瘤。

研究设计与样本

  • 回顾性剂量学分析,连续选择9例胰腺癌患者,采用4DCT勾画靶区与危及器官,非共面IMRT治疗,每周行CBCT进行气柱充盈评估、等中心验证并回顾性计算剂量。

关键影像表现/征象

  • 每周CBCT与4DCT之间腹部气柱变化幅度可达±80%。
  • 即使治疗路径中存在如此大的气柱,胰腺癌前后径变化极小,仅为2.8%。

局限性

  • 原文为回顾性研究,样本为9例连续患者。
  • 原文结论提出该技术可能优于3DCRT,并指出需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer.

METHODS: Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively.

RESULTS: Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed.

CONCLUSION: CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Estabrook NC, Corn JB, Ewing MM, et al. Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer. Br J Radiol. 2017. PMID: 29166133. doi:10.1259/bjr.20170512

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。