二维剪切波弹性成像对丙氨酸氨基转移酶升高患者肝纤维化无创分期的诊断准确性
本研究评估二维剪切波弹性成像(2-D-SWE)对丙氨酸氨基转移酶(ALT)升高(>5倍正常上限)的慢性肝病患者肝纤维化分期的诊断准确性,并与天冬氨酸氨基转移酶-血小板指数和纤维化-4指数两种生化标志物比较。共分析105例患者的肝活检数据,2-D-SWE诊断显著纤维化、严重纤维化和肝硬化的AUROC分别为0.83、0.86和0.91,最佳截断值分别为10.6、13.2和17.6 kPa,均显著高于生化标志物(所有p值<0.05)。
要点
- ALT>5倍正常上限患者中,2-D-SWE诊断肝硬化AUROC达0.91,最佳截断值17.6 kPa。
- 显著纤维化、严重纤维化、肝硬化截断值分别为10.6、13.2、17.6 kPa,均高于常规阈值。
- 2-D-SWE诊断各期纤维化的AUROC均显著高于AST-血小板指数和FIB-4(所有p<0.05)。
核心结论
- 在ALT升高(>5倍正常上限)的慢性肝病患者中,2-D-SWE对肝纤维化分期的诊断性能有前景,其AUROC显著高于生化标志物,但最佳截断值升高。
研究设计与样本
- 连续纳入接受肝活检的慢性肝病且ALT升高患者,最终分析105例数据;构建ROC曲线评估总体准确性和最佳截断值,并与天冬氨酸氨基转移酶-血小板指数和纤维化-4指数比较。
诊断标准与关键数值
- 2-D-SWE诊断显著纤维化、严重纤维化和肝硬化的AUROC分别为0.83、0.86和0.91,最佳截断值分别为10.6、13.2和17.6 kPa;各期AUROC均显著高于生化标志物(所有p值<0.05)。
临床应用与阅片要点
- 对ALT>5倍正常上限患者行2-D-SWE时,应采用本研究升高的截断值(显著纤维化10.6 kPa、严重纤维化13.2 kPa、肝硬化17.6 kPa)判读,因该类患者肝硬度基线水平升高,即使无纤维化亦如此。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This study assessed the diagnostic accuracy of 2-D shear wave elastography (2-D-SWE) for the non-invasive staging of liver fibrosis and compared the findings with those for biochemical markers (the aspartate aminotransferase-to-platelet index and fibrosis-4 index) of liver fibrosis in patients with elevated alanine aminotransferase (ALT) levels (>5 × the upper limit of normal). Patients with chronic liver diseases and elevated ALT levels who underwent liver biopsy were consecutively included. Receiver operating characteristic (ROC) curves were constructed to assess overall accuracy and to identify optimal cutoff values. After exclusions, data from 105 patients were analyzed. The areas under the ROC curves (AUROCs) for significant fibrosis, severe fibrosis and cirrhosis were 0.83, 0.86 and 0.91, respectively. The optimal cutoff values for predicting significant fibrosis, severe fibrosis and cirrhosis were 10.6, 13.2 and 17.6 kPa, respectively. The AUROCs of 2-D-SWE were significantly higher than those of biochemical markers for predicting significant fibrosis, severe fibrosis and cirrhosis (all p values < 0.05). Therefore, the diagnostic performance of 2-D-SWE in assessing liver fibrosis stages in patients with elevated ALT levels was promising. The optimal cutoff values were increased but appropriate for this cohort because the baseline levels of liver stiffness measurements were increased in these patients, even in the absence of fibrosis.
引用
- Zeng J, Huang Z, Jin J, et al. Diagnostic Accuracy of 2-D Shear Wave Elastography for the Non-Invasive Staging of Liver Fibrosis in Patients with Elevated Alanine Aminotransferase Levels. Ultrasound Med Biol. 2017. PMID: 29122316. doi:10.1016/j.ultrasmedbio.2017.09.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。