技术报告:钆塞酸二钠增强二维R2*成像评估活体供肝者胆管的新方法
本研究纳入10例活体肝移植供体候选者,在注射钆塞酸二钠20分钟后行3T MRI,采集三维T1加权MR胆管成像和二维T1加权多回波 spoiled 梯度回波序列并生成R2*图。三位放射科医师回顾性独立评分8个胆管段显示情况,结果显示二维R2*图在右前、右后、2段、3段和4段胆管显示评分显著高于三维T1加权MR胆管成像。作者认为二维R2*图评估活体供肝胆管可行,可能成为活体肝移植供体MR方案的有价值补充。
要点
- 二维R2*图在右前、右后、2段、3段和4段胆管显示评分显著高于三维T1加权MR胆管成像。
- 所有供体均耐受检查,R2*图在所有病例中成功生成。
- 作者认为二维R2*图可能成为活体肝移植供体MR方案的有价值补充。
核心结论
- 钆塞酸二钠增强二维R2*成像评估活体供肝胆管可行,可能成为活体肝移植供体MR方案的有价值补充,用于描绘肝内胆管解剖。
研究设计与样本
- 技术可行性研究,纳入10例活体肝移植供体候选者,术前3T MRI注射钆塞酸二钠20分钟后采集三维T1加权MR胆管成像和二维T1加权多回波 spoiled 梯度回波序列,由三位放射科医师回顾性独立评分。
关键影像表现/征象
- 二维R2*图在右前胆管显示评分显著高于三维T1加权MR胆管成像(p=0.003)。
- 二维R2*图在右后胆管显示评分显著高于三维T1加权MR胆管成像(p=0.0001)。
- 二维R2*图在2段胆管显示评分显著高于三维T1加权MR胆管成像(p<0.0001)。
- 二维R2*图在3段胆管显示评分显著高于三维T1加权MR胆管成像(p=0.0001)。
- 二维R2*图在4段胆管显示评分显著高于三维T1加权MR胆管成像(p<0.0001)。
诊断标准与关键数值
- 对8个胆管段显示情况采用4分有序量表评分,评分越高表示显示越好。
临床应用与阅片要点
- 作者认为钆塞酸二钠增强二维R2*成像可能成为活体肝移植供体MR方案的有价值补充,用于描绘肝内胆管解剖。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Gadoxetate-disodium (Gd-EOB-DTPA)-enhanced 3D T1- weighted (T1w) MR cholangiography (MRC) is an efficient method to evaluate biliary anatomy due to T1 shortening of excreted contrast in the bile. A method that exploits both T1 shortening and T2* effects may produce even greater bile duct conspicuity. The aim of our study is to determine feasibility and compare the diagnostic performance of two-dimensional (2D) T1w multi-echo (ME) spoiled gradient-recalled-echo (SPGR) derived R2* maps against T1w MRC for bile duct visualization in living liver donor candidates.
MATERIALS AND METHODS: Ten potential living liver donor candidates underwent pretransplant 3T MRI and were included in our study. Following injection of Gd-EOBDTPA and a 20-min delay, 3D T1w MRC and 2D T1w ME SPGR images were acquired. 2D R2* maps were generated inline by the scanner assuming exponential decay. The 3D T1w MRC and 2D R2* maps were retrospectively and independently reviewed in two separate sessions by three radiologists. Visualization of eight bile duct segments was scored using a 4-point ordinal scale. The scores were compared using mixed effects regression model.
RESULTS: Imaging was tolerated by all donors and R2* maps were successfully generated in all cases. Visualization scores of 2D R2* maps were significantly higher than 3D T1w MRC for right anterior (p = 0.003) and posterior (p = 0.0001), segment 2 (p < 0.0001), segment 3 (p = 0.0001), and segment 4 (p < 0.0001) ducts.
CONCLUSIONS: Gd-EOB-DTPA-enhanced 2D R2* mapping is a feasible method for evaluating the bile ducts in living donors and may be a valuable addition to the living liver donor MR protocol for delineating intrahepatic biliary anatomy.
引用
- Fazeli Dehkordy S, Fowler KJ, Wolfson T, et al. Technical report: gadoxetate-disodium-enhanced 2D R2* mapping: a novel approach for assessing bile ducts in living donors. Abdom Radiol (NY). 2018. PMID: 29086007. doi:10.1007/s00261-017-1365-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。