文献速递腹部CTMRPET

病例248:囊性十二指肠萎缩伴沟槽状胰腺炎

Case 248: Cystic Duodenal Dystrophy with Groove Pancreatitis.
PubMed 文献 · Radiology · 2017-01-01

59岁男性因急性上腹痛就诊,既往有类似腹痛并接受手术史,多次上消化道内镜检查失败。实验室检查示γ-谷氨酰转移酶210 U/L、碱性磷酸酶157 U/L、淀粉酶210 U/L、脂肪酶391 U/L升高,总蛋白4.6 g/dL、白蛋白2.6 g/dL降低。患者接受立位腹部X线摄影、增强多排CT、PET/CT及上腹部MR检查。

要点

  • 囊性十二指肠萎缩伴沟槽状胰腺炎可表现为上腹痛及胰酶、胆汁淤积酶升高。
  • 多次上消化道内镜检查失败可能提示十二指肠存在结构异常。
  • 影像学检查(CT、PET/CT、MR)用于评估十二指肠及胰腺沟槽区域异常。

核心结论

  • 本病例为囊性十二指肠萎缩伴沟槽状胰腺炎,表现为急性上腹痛及实验室检查异常。

研究设计与样本

  • 病例报告,1例59岁男性患者,接受立位腹部X线摄影、增强多排CT(iohexol 100 mL,300 mg碘/mL)、PET/CT(FDG 6.9 mCi)及上腹部MR检查。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

History A 59-year-old man presented to the gastroenterology outpatient department with acute abdominal pain centered in the epigastrium. He had experienced similar episodes of abdominal pain in the past that had been treated with surgery. He reported multiple failed attempts at upper gastrointestinal endoscopy. Laboratory tests were performed at the time of admission and revealed a serum glutamic-oxaloacetic transaminase level of 9 U/L [0.15 μkat/L] (normal range, 5-40 U/L [0.08-0.67 μkat/L]), a serum glutamic-pyruvic transaminase level of 34 U/L [0.57 μkat/L] (normal range, 5-45 U/L [0.08-0.75 μkat/L]), a serum γ-glutamyltransferase level of 210 U/L (3.50 μkat/L) (normal range, 10-50 U/L [0.17-0.83 μkat/L]), a serum alkaline phosphatase level of 157 U/L (2.62 μkat/L) (normal range, 30-120 U/L [0.50-2.0 μkat/L]), a serum amylase level of 210 U/L (3.50 μkat/L) (normal range, 30-100 U/L [0.50-1.66 μkat/L]), a serum lipase level of 391 U/L (6.52 μkat/L) (normal range, 13-60 U/L [0.21-1.0 μkat/L]), an α-fetoprotein level of 3.81 ng/ mL (normal range, 0-9 ng/mL), a total protein level of 4.6 g/dL (normal range, 6.0-8.5 g/dL), and an albumin level of 2.6 g/dL (normal range, 3.5-5.2 g/dL). The rest of the laboratory data were unremarkable. The patient underwent erect abdominal radiography, contrast material-enhanced multidetector row computed tomography (CT) of the abdomen with 100 mL of iohexol (300 mg iodine per milliliter, Omnipaque; GE Healthcare, Shanghai, China) followed by combined positron emission tomography (PET) and CT (hereafter, PET/CT) with 6.9 mCi of fluorodeoxyglucose (FDG) and magnetic resonance (MR) imaging of the upper abdomen.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Patil AR, Nandikoor S, Mallarajapatna G, et al. Case 248: Cystic Duodenal Dystrophy with Groove Pancreatitis. Radiology. 2017. PMID: 29155635. doi:10.1148/radiol.2017150839

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。