LI-RADS 2014版算法及肝细胞癌诊断影像特征的阅片者间可靠性:一项大型国际多阅片者研究
该回顾性多中心多阅片者研究纳入113名阅片者评估380组图像集,LI-RADS 2014版最终分类的组内相关系数(ICC)CT为0.67、MR为0.73,主要影像特征ICC高(0.84–0.87),阅片者人口学特征影响极小。
要点
- LI-RADS 2014版最终分类的阅片者间可靠性为良好:CT ICC 0.67,MR ICC 0.73。
- 主要影像特征可靠性高:动脉期高强化ICC 0.87、廓清表现0.85、包膜表现0.84。
- 肝脏专业经验、LI-RADS熟悉程度及住院医师后执业年限对ICC无显著影响。
核心结论
- LI-RADS 2014版最终分类的ICC为良好,主要特征判读的ICC为高,阅片者人口学特征影响极小;采用非连续检查的精选图像集所得结果不一定与既往连续检查系列研究可比。
研究设计与样本
- 回顾性多中心多阅片者研究,经机构审查委员会批准并豁免患者知情同意;10组图像集共38–40个独立检查(CT与MR数量相等,LI-RADS分类均匀分布)随机分配给阅片者;图像包括平扫及标准对比剂增强期相,并提供观察病灶直径与生长数据;113名阅片者共评估380组图像集;采用混合模型回归分析的组内相关系数(ICC)评估阅片者间可靠性。
诊断标准与关键数值
- 最终LI-RADS分类的ICC:CT为0.67(95%CI:0.61,0.71),MR为0.73(95%CI:0.68,0.77)。
- 动脉期高强化的ICC为0.87(95%CI:0.84,0.90)。
- 廓清表现的ICC为0.85(95%CI:0.81,0.88)。
- 包膜表现的ICC为0.84(95%CI:0.80,0.87)。
临床应用与阅片要点
- 肝脏专业经验、LI-RADS熟悉程度或住院医师后执业年限对ICC无显著影响(ICC范围0.69–0.70;ICC差值0.003–0.01,95%CI:-0.003至-0.01,0.004–0.02)。
- 私立执业阅片者的ICC较学术机构阅片者边缘性更高(ICC差值0.009;95%CI:0.000,0.021)。
局限性
- 采用非连续检查的精选图像集所得结果不一定与既往采用连续检查系列的研究可比。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To determine in a large multicenter multireader setting the interreader reliability of Liver Imaging Reporting and Data System (LI-RADS) version 2014 categories, the major imaging features seen with computed tomography (CT) and magnetic resonance (MR) imaging, and the potential effect of reader demographics on agreement with a preselected nonconsecutive image set. Materials and Methods Institutional review board approval was obtained, and patient consent was waived for this retrospective study. Ten image sets, comprising 38-40 unique studies (equal number of CT and MR imaging studies, uniformly distributed LI-RADS categories), were randomly allocated to readers. Images were acquired in unenhanced and standard contrast material-enhanced phases, with observation diameter and growth data provided. Readers completed a demographic survey, assigned LI-RADS version 2014 categories, and assessed major features. Intraclass correlation coefficient (ICC) assessed with mixed-model regression analyses was the metric for interreader reliability of assigning categories and major features. Results A total of 113 readers evaluated 380 image sets. ICC of final LI-RADS category assignment was 0.67 (95% confidence interval [CI]: 0.61, 0.71) for CT and 0.73 (95% CI: 0.68, 0.77) for MR imaging. ICC was 0.87 (95% CI: 0.84, 0.90) for arterial phase hyperenhancement, 0.85 (95% CI: 0.81, 0.88) for washout appearance, and 0.84 (95% CI: 0.80, 0.87) for capsule appearance. ICC was not significantly affected by liver expertise, LI-RADS familiarity, or years of postresidency practice (ICC range, 0.69-0.70; ICC difference, 0.003-0.01 [95% CI: -0.003 to -0.01, 0.004-0.02]. ICC was borderline higher for private practice readers than for academic readers (ICC difference, 0.009; 95% CI: 0.000, 0.021). Conclusion ICC is good for final LI-RADS categorization and high for major feature characterization, with minimal reader demographic effect. Of note, our results using selected image sets from nonconsecutive examinations are not necessarily comparable with those of prior studies that used consecutive examination series. © RSNA, 2017.
引用
- Fowler KJ, Tang A, Santillan C, et al. Interreader Reliability of LI-RADS Version 2014 Algorithm and Imaging Features for Diagnosis of Hepatocellular Carcinoma: A Large International Multireader Study. Radiology. 2017. PMID: 29091751. doi:10.1148/radiol.2017170376
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。