文献速递腹部技术与安全MR

表观扩散系数在鉴别胰腺神经内分泌肿瘤与胰内副脾中的准确性

Accuracy of apparent diffusion coefficient in differentiating pancreatic neuroendocrine tumour from intrapancreatic accessory spleen.
PubMed 文献 · Eur Radiol · 2017-11-13

研究纳入62例胰腺神经内分泌肿瘤(NET,n=51)或胰内副脾(IPAS,n=11)患者,由两名独立阅片者测量病灶及脾脏ADC值。胰腺NET的绝对ADC和归一化ADC均显著高于IPAS,两种方法鉴别诊断的AUC相似(88.2% vs 88.8%,P=0.899),阅片者间信度均优秀。

要点

  • 胰腺NET绝对ADC显著高于IPAS(1.431×10⁻³ vs 0.967×10⁻³ mm²/s,P<0.0001)。
  • 绝对ADC≥1.206×10⁻³ mm²/s诊断NET的敏感度70.6%、特异度90.9%。
  • 病灶/脾脏ADC比值≥1.25敏感度80.4%、特异度81.8%;≥1.29敏感度74.5%、特异度100%。

核心结论

  • 绝对ADC和归一化ADC均可实现胰腺NET与IPAS的临床相关鉴别,两者AUC相似(88.2% vs 88.8%,P=0.899),阅片者间信度均优秀。

研究设计与样本

  • 研究纳入62例患者,其中胰腺NET 51例、IPAS 11例;两名独立阅片者测量所有病灶及脾脏的ADC值,采用ROC分析比较绝对ADC与归一化ADC(病灶/脾脏ADC比值)的鉴别效能,并评估两种方法的阅片者间信度。

诊断标准与关键数值

  • 绝对ADC≥1.206×10⁻³ mm²/s诊断胰腺NET(对比IPAS)的敏感度70.6%、特异度90.9%。
  • 病灶/脾脏ADC比值≥1.25鉴别胰腺NET与IPAS的敏感度80.4%、特异度81.8%。
  • 病灶/脾脏ADC比值≥1.29鉴别胰腺NET与IPAS的敏感度74.5%、特异度100%。
  • 绝对ADC与归一化ADC的AUC分别为88.2%与88.8%,两者比较P=0.899。
  • 绝对ADC与ADC比值的组内相关系数(ICC)分别为0.957与0.927。

临床应用与阅片要点

  • 胰腺NET的绝对ADC(1.431×10⁻³ mm²/s)显著高于IPAS(0.967×10⁻³ mm²/s),P<0.0001。
  • 胰腺NET的归一化ADC(1.59)显著高于IPAS(1.09),P<0.0001。
  • 脾脏ADC uniquely 低,可用于区分IPAS与胰腺NET。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate and compare the accuracy of absolute apparent diffusion coefficient (ADC) and normalised ADC (lesion-to-spleen ADC ratio) in differentiating pancreatic neuroendocrine tumour (NET) from intrapancreatic accessory spleen (IPAS).

METHODS: Study included 62 patients with the diagnosis of pancreatic NET (n=51) or IPAS (n=11). Two independent reviewers measured ADC on all lesions and spleen. Receiver operating characteristics (ROC) analysis to differentiate NET from IPAS was performed and compared for absolute and normalised ADC. Inter-reader reliability for the two methods was assessed.

RESULTS: Pancreatic NET had significantly higher absolute ADC (1.431x10-3 vs 0.967x10-3 mm2/s; P<0.0001) and normalised ADC (1.59 vs 1.09; P<0.0001) compared to IPAS. An ADC value of ≥1.206x10-3 mm2/s was 70.6% sensitive and 90.9% specific for the diagnosis of NET vs. IPAS. Lesion to spleen ADC ratio of ≥1.25 was 80.4% sensitive, and 81.8% specific while ratio of ≥1.29 was 74.5% sensitive and 100% specific in the differentiation. The area under the curve (AUCs) for two methods were similar (88.2% vs. 88.8%; P=0.899). Both methods demonstrated excellent inter-reader reliability with ICCs for absolute ADC and ADC ratio being 0.957 and 0.927, respectively.

CONCLUSION: Both absolute and normalised ADC allow clinically relevant differentiation of pancreatic NET and IPAS.

KEY POINTS: • Imaging overlaps between IPASs and pancreatic-NETs lead to unnecessary procedures including pancreatectomy. • Uniquely low ADC of spleen allows differentiating IPASs from pancreatic NETs. • Both absolute-ADC and normalised-ADC (lesion-to-spleen ADC-ratio) demonstrate high accuracy in differentiating IPASs from NETs. • Both methods demonstrate excellent inter-reader reliability.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pandey A, Pandey P, Ghasabeh MA, et al. Accuracy of apparent diffusion coefficient in differentiating pancreatic neuroendocrine tumour from intrapancreatic accessory spleen. Eur Radiol. 2017. PMID: 29134352. doi:10.1007/s00330-017-5122-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。