潜在活体肝移植供者肝血管解剖成像:钆塞酸二钠增强CAIPIRINHA技术MR血管成像与CT血管成像的比较
回顾性纳入82例潜在活体肝移植供者,以CTA为参考标准,评估钆塞酸二钠增强CAIPIRINHA技术MRA对肝血管解剖变异的判断准确性。MRA判断肝动脉、门静脉、肝静脉变异及IV段动脉起源的准确性分别为73%、90%、79%、55%;MRA显示肝动脉的主观图像质量显著低于CTA(p<0.001),门静脉和肝静脉图像质量两者几乎相当(p=0.059),仅左肝静脉在CT上显示更好(p=0.023)。
要点
- MRA判断门静脉和肝静脉变异的准确性较好(分别为90%和79%),与CTA图像质量几乎相当。
- MRA判断肝动脉变异的准确性中等(73%),且肝动脉图像质量显著低于CTA(p<0.001)。
- MRA仅约半数供者可明确显示IV段动脉起源,准确性为55%。
核心结论
- 钆塞酸二钠增强CAIPIRINHA技术MRA用于潜在活体肝移植供者肝血管解剖成像可行,与CTA相比,动脉变异判断准确性中等,肝静脉和门静脉变异判断结果为好至优秀;但仅略超过半数供者可通过MRA明确显示IV段动脉起源。
研究设计与样本
- 回顾性研究,纳入82例同时接受MRA和CTA的潜在活体肝移植供者,符合HIPAA并经IRB批准;由两名阅片者共识评估MRA和CTA图像质量评分及MRA判断肝血管变异的准确性,以CTA为参考标准,图像质量评分采用Fisher精确检验比较。
诊断标准与关键数值
- 以CTA为参考标准,MRA判断肝动脉变异、门静脉变异、肝静脉变异及IV段动脉起源的准确性分别为73%、90%、79%、55%;MRA显示肝动脉的主观图像质量显著低于CTA(p<0.001),门静脉和肝静脉图像质量两者几乎相当(p=0.059),仅左肝静脉在CT图像上显示更好(p=0.023)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To retrospectively evaluate gadoxetic acid-enhanced magnetic resonance angiography (MRA) using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique for mapping hepatic vascular anatomy in potential living liver donors, with CT angiography (CTA) as reference standard.
METHODS: 82 potential living liver donors who underwent MRA and CTA were enrolled in this HIPAA-compliant IRB-approved study. MRA and CTA images were evaluated by two reviewers in consensus with respect to (1) image quality scores for depiction of the hepatic vessels and (2) accuracy of MRA for determining the hepatic vascular variants with CTA as reference standard. The image quality scores were compared using Fisher's exact test between MRA and CTA.
RESULTS: The accuracy for determining the hepatic arterial, portal, and hepatic venous variants and segment IV arterial origin was 73, 90, 79, and 55%, respectively, compared to CTA. However, subjective image quality for depiction of hepatic arteries in MRA was significantly lower than CTA (p < 0.001). The portal and hepatic venous image quality was almost equal in both modalities (p = 0.059) except left hepatic vein being depicted better on CT images (p = 0.023).
CONCLUSION: Gadoxetic acid-enhanced MRA using CAIPIRINHA technique is feasible for mapping hepatic vasculature in potential living liver donors, with moderate accuracy for arterial variants and good to excellent results for hepatic and portal vein variants, compared with CTA. However, the specific delineation of segment IV arterial origin was possible in just over half of the liver donors with MRA.
引用
- Jhaveri K, Guo L, Guimarães L, et al. Mapping of hepatic vasculature in potential living liver donors: comparison of gadoxetic acid-enhanced MR imaging using CAIPIRINHA technique with CT angiography. Abdom Radiol (NY). 2018. PMID: 29128992. doi:10.1007/s00261-017-1379-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。