文献速递技术与安全US

长循环脂质包覆微泡的声学特性及增强超声成像

Acoustic Characterization and Enhanced Ultrasound Imaging of Long-Circulating Lipid-Coated Microbubbles.
PubMed 文献 · J Ultrasound Med · 2017-11-11

研究通过改变 SonoVue 微泡的气体核心制备长循环脂质包覆微泡,并以 SonoVue 为对照进行体内外声学与成像评估;合成微泡平均直径 1.484 μm,在约 2.8 MHz 共振,壳弹性 0.2 ± 0.09 N/m 与 SonoVue 相当,但黏性和惯性空化更高,体内循环时间更长、抗快速崩溃能力更强,可能在肝脏获得更持久增强。

要点

  • 合成微泡平均直径 1.484 μm,在约 2.8 MHz 共振。
  • 合成微泡壳弹性 0.2 ± 0.09 N/m,与 SonoVue 相当。
  • 合成微泡较 SonoVue 循环时间更长,抗快速崩溃能力更强。

核心结论

  • 仅改变 SonoVue 微泡的核心气体组成即可制备纳米/微米级长循环脂质包覆微泡,其更小直径和更高惯性空化阈值可能更易到达深部器官并在肝脏产生更持久成像增强。

研究设计与样本

  • 研究合成一种与 SonoVue 微泡脂质壳相似的超声造影微泡,以 SonoVue 为对照组进行体内成像评估,并进行粒径分布、惯性空化阈值及声衰减测量。

诊断标准与关键数值

  • 合成微泡呈球形、膜光滑一致、分布均匀,平均直径 1.484 μm。
  • 声衰减曲线显示合成微泡在约 2.8 MHz 共振。
  • 合成微泡壳弹性为 0.2 ± 0.09 N/m,与 SonoVue 相当。
  • 合成微泡因气体核心不同而具有相对更高的黏度和惯性空化。

临床应用与阅片要点

  • 合成微泡在体内循环时间较 SonoVue 更长,对抗快速崩溃的机会优于 SonoVue。
  • 合成微泡更小直径和更高惯性空化阈值可能使其更易到达深部器官,并在肝脏给出延长成像增强。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: A long-circulating lipid-coated ultrasound (US) contrast agent was fabricated to achieve a longer wash-out time and gain more resistance against higher-mechanical index sonication. Systemic physical, acoustic, and in vivo imaging experiments were performed to better understand the underlying mechanism enabling the improvement of contrast agent performance by adjusting the physical and acoustic properties of contrast agent microbubbles.

METHODS: By simply altering the gas core, a kind of US contrast agent microbubble was synthesized with a similar lipid-coating shell as SonoVue microbubbles (Bracco SpA, Milan, Italy) to achieve a longer wash-out time and higher inertial cavitation threshold. To bridge the structure-performance relationship of the synthesized microbubbles, the imaging performance of the microbubbles was assessed in vivo with SonoVue as a control group. The size distribution and inertial cavitation threshold of the synthesized microbubbles were characterized, and the shell parameters of the microbubbles were determined by acoustic attenuation measurements. All of the measurements were compared with SonoVue microbubbles.

RESULTS: The synthesized microbubbles had a spherical shape, a smooth, consistent membrane, and a uniform distribution, with an average diameter of 1.484 μm. According to the measured attenuation curve, the synthesized microbubbles resonated at around 2.8 MHz. Although the bubble's shell elasticity (0.2 ± 0.09 N/m) was comparable with SonoVue, it had relatively greater viscosity and inertial cavitation because of the different gas core. Imaging studies showed that the synthesized microbubbles had a longer circulation time and a better chance of fighting against rapid collapse than SonoVue.

CONCLUSIONS: Nano/micrometer long-circulating lipid-coated microbubbles could be fabricated by simply altering the core composition of SonoVue microbubbles with a higher-molecular weight gas. The smaller diameter and higher inertial cavitation threshold of the synthesized microbubbles might make it easier to access deep-seated organs and give prolonged imaging enhancement in the liver.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li H, Yang Y, Zhang M, et al. Acoustic Characterization and Enhanced Ultrasound Imaging of Long-Circulating Lipid-Coated Microbubbles. J Ultrasound Med. 2017. PMID: 29127707. doi:10.1002/jum.14470

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。