文献速递心血管CT

冠状动脉CT血管造影估算中间病变的血流储备分数:不同冠状动脉血流分布测定方法的诊断准确性比较

Fractional Flow Reserve Estimated at Coronary CT Angiography in Intermediate Lesions: Comparison of Diagnostic Accuracy of Different Methods to Determine Coronary Flow Distribution.
PubMed 文献 · Radiology · 2017-11-20

本横断面研究在61例CT血管造影显示中间直径狭窄(25%-69%)的患者中,比较三种CT血流储备分数(CT FFR)算法(Murray定律、Huo-Kassab规则、对比剂充盈梯度)对血流储备分数≤0.8的诊断准确性。以对比剂梯度估算血流分布的AUC为0.953,显著高于Huo-Kassab规则(AUC=0.882,P=.043)和Murray定律(AUC=0.871,P=.033),三者均高于CT血管造影直径狭窄≥50%的AUC(0.596,P<.001)。结论认为临床医生可在现场采用四步法CT FFR准确检测血流动力学显著的中间狭窄病变,利用冠状动脉对比剂充盈差异估算血流分布可能提高CT FFR准确性。

要点

  • CT FFR采用对比剂充盈梯度估算血流分布时AUC为0.953,高于Huo-Kassab规则(0.882)和Murray定律(0.871)。
  • 三种CT FFR算法的AUC均高于CT血管造影直径狭窄≥50%的AUC(0.596,P<.001)。
  • CT FFR与FFR相关性以对比剂梯度最高(Spearman ρ=0.80),其次为Huo-Kassab规则(ρ=0.68)和Murray定律(ρ=0.67)。

核心结论

  • 临床医生可在现场采用四步法CT FFR准确检测血流动力学显著的中间狭窄病变,利用冠状动脉对比剂充盈差异估算血流分布可能提高CT FFR准确性。

研究设计与样本

  • 横断面研究,符合HIPAA并经人体研究委员会批准,纳入61例CT血管造影显示中间直径狭窄(25%-69%)且在90天内接受FFR测量的患者(平均年龄69岁±10,年龄范围29-89岁),比较三种CT FFR算法估算血流分布。

诊断标准与关键数值

  • 以FFR≤0.8为参考标准,对比剂梯度法CT FFR的AUC=0.953,Huo-Kassab规则AUC=0.882(与梯度法比较P=.043),Murray定律AUC=0.871(与梯度法比较P=.033),CT血管造影直径狭窄≥50%的AUC=0.596(与三种CT FFR算法比较均P<.001)。

临床应用与阅片要点

  • 作者结论认为临床医生可在现场采用四步法CT FFR准确检测血流动力学显著的中间狭窄病变,利用冠状动脉对比剂充盈差异估算血流分布可能提高CT FFR准确性;CT FFR与FFR的相关性以对比剂梯度最高(Spearman ρ=0.80),其次为Huo-Kassab规则(ρ=0.68)和Murray定律(ρ=0.67)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare the diagnostic accuracy of different computed tomographic (CT) fractional flow reserve (FFR) algorithms for vessels with intermediate stenosis. Materials and Methods This cross-sectional HIPAA-compliant and human research committee-approved study applied a four-step CT FFR algorithm in 61 patients (mean age, 69 years ± 10; age range, 29-89 years) with a lesion of intermediate-diameter stenosis (25%-69%) at CT angiography who underwent FFR measurement within 90 days. The per-lesion diagnostic performance of CT FFR was tested for three different approaches to estimate blood flow distribution for CT FFR calculation. The first two, the Murray law and the Huo-Kassab rule, used coronary anatomy; the third used contrast material opacification gradients. CT FFR algorithms and CT angiography percentage diameter stenosis (DS) measurements were compared by using the area under the receiver operating characteristic curve (AUC) to detect FFRs of 0.8 or lower. Results Twenty-five lesions (41%) had FFRs of 0.8 or lower. The AUC of CT FFR determination by using contrast material gradients (AUC = 0.953) was significantly higher than that of the Huo-Kassab (AUC = 0.882, P = .043) and Murray law models (AUC = 0.871, P = .033). All three AUCs were higher than that for 50% or greater DS at CT angiography (AUC = 0.596, P < .001). Correlation of CT FFR with FFR was highest for gradients (Spearman ρ = 0.80), followed by the Huo-Kassab rule (ρ = 0.68) and Murray law (ρ = 0.67) models. All CT FFR algorithms had small biases, ranging from -0.015 (Murray) to -0.049 (Huo-Kassab). Limits of agreement were narrowest for gradients (-0.182, 0.147), followed by the Huo-Kassab rule (-0.246, 0.149) and the Murray law (-0.285, 0.256) models. Conclusion Clinicians can perform CT FFR by using a four-step approach on site to accurately detect hemodynamically significant intermediate-stenosis lesions. Estimating blood flow distribution by using coronary contrast opacification variations may improve CT FFR accuracy. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kishi S, Giannopoulos AA, Tang A, et al. Fractional Flow Reserve Estimated at Coronary CT Angiography in Intermediate Lesions: Comparison of Diagnostic Accuracy of Different Methods to Determine Coronary Flow Distribution. Radiology. 2017. PMID: 29156145. doi:10.1148/radiol.2017162620

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。