文献速递心血管CT

新型心动周期内运动校正算法对双能光谱冠状动脉CT血管成像的影响:高心率搏动冠状动脉体模研究

Effect of a Novel Intracycle Motion Correction Algorithm on Dual-Energy Spectral Coronary CT Angiography: A Study with Pulsating Coronary Artery Phantom at High Heart Rates.
PubMed 文献 · Korean J Radiol · 2017-09-21

本研究利用搏动冠状动脉体模,在60-100次/分心率下采用双能光谱CT模式扫描,重建50-90 keV虚拟单能图像,比较运动校正算法(MCA)与常规算法(CA)的图像质量和可判读节段比例。结果显示,在高心率(70-100次/分)下,低keV单能图像结合MCA可提高图像质量评分和可判读性。

要点

  • 在高心率(70-100次/分)下,MCA较CA提高50、60、70 keV单能图像的质量评分(p<0.05)。
  • 100次/分时,MCA提高50 keV(69.4%→86.1%)、60 keV(55.6%→83.3%)、70 keV(33.3%→69.3%)的可判读比例(p<0.05)。
  • 低keV单能图像结合MCA可改善高心率CCTA的图像质量和可判读性。

核心结论

  • 低keV单能图像结合MCA可改善高心率下CCTA的图像质量和图像可判读性。

研究设计与样本

  • 体模研究,使用搏动冠状动脉血流体模,在60-100次/分心率(每10次/分递增)下采用双能光谱CT模式扫描,重建50-90 keV(每10 keV递增)虚拟单能图像,由两名盲法观察者采用4分Likert量表(1=不可诊断,4=优秀)评估图像质量,比较MCA与常规算法(CA)。

诊断标准与关键数值

  • 图像质量采用4分Likert量表(1=不可诊断,4=优秀);在70、80、90、100次/分心率下,MCA较CA在50、60、70 keV单能水平图像评分更高(各p<0.05);90次/分时,MCA在60 keV(p<0.05)和70 keV(p<0.05)提高图像可判读性;100次/分时,MCA在50 keV(从69.4%到86.1%,p<0.05)、60 keV(从55.6%到83.3%,p<0.05)和70 keV(从33.3%到69.3%,p<0.05)提高图像可判读性。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Using a pulsating coronary artery phantom at high heart rate settings, we investigated the efficacy of a motion correction algorithm (MCA) to improve the image quality in dual-energy spectral coronary CT angiography (CCTA).

MATERIALS AND METHODS: Coronary flow phantoms were scanned at heart rates of 60-100 beats/min at 10-beats/min increments, using dual-energy spectral CT mode. Virtual monochromatic images were reconstructed from 50 to 90 keV at 10-keV increments. Two blinded observers assessed image quality using a 4-point Likert Scale (1 = non-diagnostic, 4 = excellent) and the fraction of interpretable segments using MCA versus conventional algorithm (CA). Comparison of variables was performed with the Wilcoxon rank sum test and McNemar test.

RESULTS: At heart rates of 70, 80, 90, and 100 beats/min, images with MCA were rated as higher image scores compared to those with CA on monochromatic levels of 50, 60, and 70 keV (each p < 0.05). Meanwhile, at a heart rate of 90 beats/min, image interpretability was improved by MCA at a monochromatic level of 60 keV (p < 0.05) and 70 keV (p < 0.05). At a heart rate of 100 beats/min, image interpretability was improved by MCA at monochromatic levels of 50 keV (from 69.4% to 86.1%, p < 0.05), 60 keV (from 55.6% to 83.3%, p < 0.05) and 70 keV (from 33.3% to 69.3%, p < 0.05).

CONCLUSION: Low-keV monochromatic images combined with MCA improves image quality and image interpretability in CCTAs at high heart rates.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Xing Y, Zhao Y, Guo N, et al. Effect of a Novel Intracycle Motion Correction Algorithm on Dual-Energy Spectral Coronary CT Angiography: A Study with Pulsating Coronary Artery Phantom at High Heart Rates. Korean J Radiol. 2017. PMID: 29089820. doi:10.3348/kjr.2017.18.6.881

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。