采用管电压适配对比剂注射方案的低管电压与高管电压冠状动脉CT血管成像的诊断准确性比较
本研究纳入120例同时接受导管血管造影和第三代双源冠状动脉CT血管成像(CCTA)的患者,按自动选择的管电压分为低管电压组(≤100 kVp,平均84 kVp)和高管电压组(>100 kVp,平均117 kVp),每组各60例,对比剂剂量按管电压水平调整。结果显示两组在患者、血管和节段水平的诊断准确性相当(所有P>0.64),图像质量相似,但低管电压组对比剂用量减少38.1%(53.6 ml vs 86.6 ml),辐射剂量减少59.6%(4.3 mSv vs 10.6 mSv)。
要点
- 低管电压(≤100 kVp)与高管电压(>100 kVp)CCTA对冠状动脉狭窄(>50%)的诊断准确性相当。
- 低管电压组对比剂用量较高管电压组减少38.1%(53.6 ml vs 86.6 ml)。
- 低管电压组辐射剂量较高管电压组减少59.6%(4.3 mSv vs 10.6 mSv)。
核心结论
- 自动管电压选择联合适配对比剂注射方案可使CCTA在≤100 kVp下完成,与>100 kVp采集相比辐射剂量和对比剂用量显著降低,而冠状动脉狭窄诊断准确性相当。
研究设计与样本
- 研究类型为诊断准确性比较研究,纳入120例患者(平均年龄62.6岁,BMI 29.0 kg/m2),均接受导管血管造影和采用自动管电压选择的第三代双源CCTA,分为低管电压组(≤100 kVp,n=60,平均84 kVp)和高管电压组(>100 kVp,n=60,平均117 kVp),对比剂剂量按管电压水平调整。
诊断标准与关键数值
- 以导管血管造影为参考标准,诊断显著冠状动脉狭窄(管腔狭窄>50%)的敏感度/特异度:低管电压组(≤100 kVp)患者水平93.9%/92.6%、血管水平91.5%/97.8%、节段水平90.0%/96.7%;高管电压组(>100 kVp)患者水平90.9%/92.6%、血管水平94.0%/96.8%、节段水平90.7%/95.2%(所有P>0.64)。
临床应用与阅片要点
- 低管电压组对比剂剂量按管电压水平调整:70 kVp对应40 ml、80 kVp对应50 ml、90 kVp对应60 ml、100 kVp对应70 ml、110 kVp对应80 ml、120 kVp对应90 ml。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol.
METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing).
RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001).
CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp.
KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.
引用
- Albrecht MH, Nance JW, Schoepf UJ, et al. Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol. Eur Radiol. 2017. PMID: 29181587. doi:10.1007/s00330-017-5150-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。