多能CT心血管应用的最新进展
本文综述多能(光谱/双能)CT在心血管疾病中的应用进展。多能CT基于源或探测器技术,在图像或投影空间进行物质分解,可生成碘图、虚拟平扫、有效原子序数、虚拟单能图像及元素级数据(CT指纹),在心肌灌注、延迟增强、肺灌注、血管对比增强及减少伪影和辐射剂量方面补充或克服常规CT的局限。
要点
- 碘图可提高心肌灌注缺损的敏感度,虚拟单能图像通过减少伪影提高特异度。
- 碘图有助于提高CT在延迟增强成像中的表现。
- 低能虚拟单能图像可增强血管对比,用于降低对比剂剂量或挽救次优对比增强检查。
核心结论
- 多能CT提供的碘图、虚拟平扫、有效原子序数、虚拟单能图像及CT指纹等图像集,可补充并在某些方面克服常规CT方法的局限。
研究设计与样本
- 综述,检索范围与纳入文献原文未报告。
关键影像表现/征象
- 心肌灌注成像中,碘图提高灌注缺损的敏感度,虚拟单能图像通过减少伪影提高特异度。
- 碘图有助于提高CT在延迟增强成像中的表现。
- 肺灌注成像中,碘图提高急性和慢性肺栓塞检测的敏感度。
- 低能(以千电子伏特计)虚拟单能图像可增强血管对比,用于降低对比剂剂量或挽救次优对比增强检查。
- 高能虚拟单能图像可减少或消除线束硬化及金属伪影。
诊断标准与关键数值
- 多能CT技术按来源分为源基(双源、快速千伏切换、双旋转、劈束)和探测器基(双层、光子计数),物质分解在图像或投影空间进行。
- 虚拟平扫图像与真实平扫图像衰减相似,可在多期血管研究中省去后者以降低辐射剂量。
- 其他潜在应用包括从冠状动脉CT血管造影创建的虚拟平扫图像进行钙化评分以及心肌铁定量。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Advances in scanner technology enabling shorter scan times, improvements in spatial and temporal resolution, and more dose-efficient data reconstruction coupled with rapidly growing evidence from clinical trials have established computed tomography (CT) as an important imaging modality in the evaluation of cardiovascular disorders. Multienergy (or spectral or dual-energy) CT is a relatively recent advance in which attenuation data from different energies are used to characterize materials beyond what is possible at conventional CT. Current technologies for multienergy CT are either source based (ie, dual source, rapid kilovoltage switching, dual spin, and split beam) or detector based (ie, dual layer and photon counting), and material-based decomposition occurs in either image or projection space. In addition to conventional diagnostic images, multienergy CT provides image sets such as iodine maps, virtual nonenhanced, effective atomic number, and virtual monoenergy (VM) images as well as data at the elemental level (CT fingerprinting), which can complement and in some areas overcome the limitations posed by conventional CT methods. In myocardial perfusion imaging, iodine maps improve the sensitivity of perfusion defects, and VM images improve the specificity by decreasing artifacts. Iodine maps are also useful in improving the performance of CT in delayed-enhancement imaging. In pulmonary perfusion imaging, iodine maps enhance the sensitivity of detection of both acute and chronic pulmonary emboli. Low-energy (as measured in kiloelectron volts) VM images allow enhancement of vascular contrast, which can either be used to lower contrast dose or salvage a suboptimal contrast-enhanced study. High-energy VM images can be used to decrease or eliminate artifacts such as beam-hardening and metallic artifacts. Virtual nonenhanced images have similar attenuation as true nonenhanced images and help in reducing radiation dose by eliminating the need for the latter in multiphasic vascular studies. Other potential applications of multienergy CT include calcium scoring from virtual nonenhanced images created from coronary CT angiograms and myocardial iron quantification. Online supplemental material is available for this article. ©RSNA, 2017.
引用
- Kalisz K, Halliburton S, Abbara S, et al. Update on Cardiovascular Applications of Multienergy CT. Radiographics. 2017. PMID: 29131773. doi:10.1148/rg.2017170100