文献速递心血管胸部CT

心脏移植受者前瞻性心电触发冠状动脉CT血管成像的图像质量

Image Quality of Prospectively ECG-Triggered Coronary CT Angiography in Heart Transplant Recipients.
PubMed 文献 · AJR Am J Roentgenol · 2017-11-01

该研究评估了50例心脏移植受者与50例匹配对照者使用256层CT前瞻性心电触发冠状动脉CTA的图像质量,共评估1270个冠状动脉节段。心脏移植组诊断级图像质量节段比例高于对照组(94.3% vs 82.9%,p<0.001),两组有效辐射剂量均较低且无显著差异(3.7 mSv vs 4.3 mSv,p=0.24)。作者认为冠状动脉CTA是心脏移植受者随访中诊断心脏移植物血管病有前景的无创替代方法。

要点

  • 心脏移植受者前瞻性心电触发冠状动脉CTA可获得诊断级图像质量,诊断级节段占94.3%。
  • 心脏移植组诊断级图像质量节段比例高于匹配对照组(94.3% vs 82.9%)。
  • 两组有效辐射剂量均较低且无显著差异(心脏移植组3.7 mSv vs 对照组4.3 mSv)。

核心结论

  • 心脏移植受者的前瞻性心电触发冠状动脉CTA检查可获得诊断级图像质量且辐射剂量低,冠状动脉CTA是心脏移植受者随访中诊断心脏移植物血管病有前景的无创替代方法。

研究设计与样本

  • 研究纳入50例心脏移植受者和50例未行心脏移植的匹配对照者,对照者按年龄、性别、体重指数、心率和冠状动脉优势型匹配,采用256层MDCT前瞻性心电触发扫描,共评估1270个冠状动脉节段。

关键影像表现/征象

  • 心脏移植组诊断级图像质量节段为624/662(94.3%),对照组为504/608(82.9%),组间差异有统计学意义(p<0.001)。
  • 运动伪影按节段采用4点Likert型量表评估。

诊断标准与关键数值

  • 心脏移植组诊断级图像质量节段624/662(94.3%)vs 对照组504/608(82.9%),p<0.001。
  • 心脏移植组中位心率74.0次/分(IQR 67.8-79.3次/分)vs 对照组73.0次/分(IQR 68.5-80.0次/分),p=0.58。
  • 心脏移植组平均有效辐射剂量3.7 mSv(IQR 2.4-4.3 mSv)vs 对照组4.3 mSv(IQR 2.6-4.3 mSv),p=0.24。

临床应用与阅片要点

  • 对心脏移植受者随访时,可考虑采用前瞻性心电触发冠状动脉CTA作为诊断心脏移植物血管病的无创替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Cardiac allograft vasculopathy (CAV) is among the top causes of death 1 year after heart transplantation (HTx). Coronary CT angiography (CTA) is a potential alternative to invasive imaging in the diagnosis of CAV. However, the higher heart rate (HR) of HTx recipients prompts the use of retrospective ECG-gating, which is associated with higher radiation dose, a major concern in this patient population. Therefore, we sought to evaluate the feasibility and image quality of low-radiation-dose prospectively ECG-triggered coronary CTA in HTx recipients.

MATERIALS AND METHODS: In total, 1270 coronary segments were evaluated in 50 HTx recipients and 50 matched control subjects who did not undergo HTx. The control subjects were selected from our clinical database and were matched for age, sex, body mass index, HR, and coronary dominance. Scans were performed using 256-MDCT with prospective ECG-triggering. The degree of motion artifacts was evaluated on a per-segment basis on a 4-point Likert-type scale.

RESULTS: The median HR was 74.0 beats/min (interquartile range [IQR], 67.8-79.3 beats/min) in the HTx group and 73.0 beats/min (IQR, 68.5-80.0 beats/min) in the matched control group (p = 0.58). In the HTx group, more segments had diagnostic image quality compared with the control group (624/662 [94.3%] vs 504/608 [82.9%]; p < 0.001). The mean effective radiation dose was low in both groups (3.7 mSv [IQR, 2.4-4.3 mSv] in the HTx group vs 4.3 mSv [IQR, 2.6-4.3 mSv] in the control group; p = 0.24).

CONCLUSION: Prospectively ECG-triggered coronary CTA examinations of HTx recipients yielded diagnostic image quality with low radiation dose. Coronary CTA is a promising noninvasive alternative to routine catheterization during follow-up of HTx recipients to diagnose CAV.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Bartykowszki A, Kolossváry M, Jermendy ÁL, et al. Image Quality of Prospectively ECG-Triggered Coronary CT Angiography in Heart Transplant Recipients. AJR Am J Roentgenol. 2017. PMID: 29091000. doi:10.2214/AJR.17.18546

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。