文献速递胸部介入CT

穿刺针道沿途肺组织最低密度值是CT引导下经皮穿刺活检后气胸的定量预测因素

Lung radiodensity along the needle passage is a quantitative predictor of pneumothorax after CT-guided percutaneous core needle biopsy.
PubMed 文献 · Clin Radiol · 2017-11-14

回顾性分析677例CT引导下经皮穿刺活检,气胸发生率40.18%,其中82.4%为轻度。多因素分析显示病灶≤2 cm、穿刺通道≥2条、针道沿途肺组织最低密度≤-850 HU是气胸独立危险因素,出血为保护因素;密度值越低,发生更严重气胸的风险越高。

要点

  • 针道沿途肺组织最低密度≤-850 HU是气胸独立危险因素(p≤0.001)。
  • 病灶≤2 cm(p=0.002)和穿刺通道≥2条(p=0.033)亦为独立危险因素。
  • 出血是气胸的保护因素(p<0.001)。

核心结论

  • 穿刺针道沿途肺组织最低密度值是气胸的定量预测因素,≤-850 HU为独立危险因素,且数值越低发生更严重气胸的风险越高。

研究设计与样本

  • 回顾性分析武汉大学中南医院677例CT引导下经皮穿刺活检(PCNB),收集年龄、性别、病灶大小、深度、位置、体位、穿刺通道数、针胸膜夹角、肺出血及针道肺密度,行单因素和多因素logistic回归。

诊断标准与关键数值

  • 病灶大小≤2 cm为气胸独立危险因素(p=0.002)。
  • 穿刺通道≥2条为气胸独立危险因素(p=0.033)。
  • 针道沿途肺组织最低密度≤-850 HU为气胸独立危险因素(p≤0.001)。
  • 出血为气胸保护因素(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To analyse whether the lowest value of lung radiodensity along the passage of the biopsy needle is a quantitative predictor of pneumothorax.

MATERIALS AND METHODS: CT-guided percutaneous core needle biopsy (PCNB) procedures performed at Zhongnan Hospital were analysed retrospectively. Age, gender, lesion size, lesion depth, lesion location, patient position, number of passages, needle pleural angle, pulmonary bleeding, and lung radiodensity along the needle passage were collected and classified by the extent of pneumothorax. Univariate analysis and multiple logistic regression analysis were assessed to explore the independent risk factors for pneumothorax.

RESULTS: Six hundred and seventy-seven cases were included in the study, including 456 males and 221 females. Pneumothorax occurred in 40.18% of cases, of which 82.4% were mild, 14% were moderate, and 3.7% were severe. Univariate and multivariate analysis showed that lesion size ≤2 cm (p=0.002), two or more passages (p=0.033), and lung radiodensity of -850 HU or less (p≤0.001) were independent risk factors for pneumothorax; bleeding (p<0.001) was a protective factor for pneumothorax.

CONCLUSIONS: The lowest value of lung radiodensity along the needle passage was a quantitative predictor of pneumothorax. A value of -850 HU or less was an independent risk factor for pneumothorax. As the value decreased, there was a higher risk of occurrence of more severe pneumothorax.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang HF, Liao MY, Zhu DY, et al. Lung radiodensity along the needle passage is a quantitative predictor of pneumothorax after CT-guided percutaneous core needle biopsy. Clin Radiol. 2017. PMID: 29150082. doi:10.1016/j.crad.2017.10.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。