文献速递胸部技术与安全PET

实验设计对PET影像组学预测体细胞突变状态的影响

Impact of experimental design on PET radiomics in predicting somatic mutation status.
PubMed 文献 · Eur J Radiol · 2017-10-09

纳入348例非小细胞肺癌患者,评估不同体素大小、滤波器和组距对66个PET影像组学特征预测体细胞突变性能的影响,以AUC衡量预测能力并用δ量化实验参数的影响。大多数特征(56个,85%)对EGFR突变状态有显著预测性(AUC≥0.61),其中29个特征对实验设置稳健(δOverall<5%);所有特征均不能预测KRAS+与KRAS-(AUC≤0.56)。

要点

  • 29个PET影像组学特征对实验设置稳健(δOverall<5%),可预测EGFR突变状态。
  • 大多数特征(56个,85%)对EGFR突变状态有显著预测性(AUC≥0.61)。
  • 所有特征均不能区分KRAS+与KRAS-(AUC≤0.56)。

核心结论

  • 29个影像组学特征的预测性能对实验设置的选择稳健,但其他所有特征需谨慎选择设置。

研究设计与样本

  • 纳入348例具有体细胞突变检测和诊断性PET图像的非小细胞肺癌患者,评估不同体素大小、滤波器和组距下的影像组学特征提取,共评估66个影像组学特征。

诊断标准与关键数值

  • 以受试者工作特征曲线下面积(AUC)评估特征预测突变状态的性能,实验参数对特征可预测性的影响量化为最小与最大AUC之间的相对差异(δ)。

临床应用与阅片要点

  • 实验设置对影像组学特征预测性能的影响不可忽视,应审慎选择体素大小、滤波器和组距等参数。

局限性

  • 需在未来研究中探索能最大化单个影像组学特征预测性能的优化设置。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: PET-based radiomic features have demonstrated great promises in predicting genetic data. However, various experimental parameters can influence the feature extraction pipeline, and hence, Here, we investigated how experimental settings affect the performance of radiomic features in predicting somatic mutation status in non-small cell lung cancer (NSCLC) patients.

METHODS: 348 NSCLC patients with somatic mutation testing and diagnostic PET images were included in our analysis. Radiomic feature extractions were analyzed for varying voxel sizes, filters and bin widths. 66 radiomic features were evaluated. The performance of features in predicting mutations status was assessed using the area under the receiver-operating-characteristic curve (AUC). The influence of experimental parameters on feature predictability was quantified as the relative difference between the minimum and maximum AUC (δ).

RESULTS: The large majority of features (n=56, 85%) were significantly predictive for EGFR mutation status (AUC≥0.61). 29 radiomic features significantly predicted EGFR mutations and were robust to experimental settings with δOverall<5%. The overall influence (δOverall) of the voxel size, filter and bin width for all features ranged from 5% to 15%, respectively. For all features, none of the experimental designs was predictive of KRAS+ from KRAS- (AUC≤0.56).

CONCLUSION: The predictability of 29 radiomic features was robust to the choice of experimental settings; however, these settings need to be carefully chosen for all other features. The combined effect of the investigated processing methods could be substantial and must be considered. Optimized settings that will maximize the predictive performance of individual radiomic features should be investigated in the future.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yip SSF, Parmar C, Kim J, et al. Impact of experimental design on PET radiomics in predicting somatic mutation status. Eur J Radiol. 2017. PMID: 29153372. doi:10.1016/j.ejrad.2017.10.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。