文献速递头颈神经MR

头颈部弥散加权成像:脂肪抑制技术与多激发二维导航交错采集的影响

Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-11-09

65 名参与者接受 3 种头颈部 3T DWI 序列,比较单激发 EPI-STIR、单激发 EPI-频谱预饱和反转恢复和多激发 EPI-频谱预饱和反转恢复。多激发 EPI-频谱预饱和反转恢复整体图像质量最佳,脂肪抑制相对均匀、变形小于单激发序列、对比噪声比高于单激发 EPI-STIR,但其测得的 ADC 值可更高,作者认为将既往报道的 ADC 值用于临床时需谨慎。

要点

  • 多激发 EPI-频谱预饱和反转恢复图像变形小于单激发 EPI 序列,各解剖区域 P < .001。
  • 单激发 EPI-STIR 脂肪抑制均匀性视觉评分除眶部外均高于其他序列(P < .05)。
  • 多激发 EPI-频谱预饱和反转恢复测得的 ADC 值可更高,作者认为将既往 ADC 值用于临床时需谨慎。

核心结论

  • 多激发 EPI-频谱预饱和反转恢复整体图像质量最佳,脂肪抑制相对均匀、变形小于单激发 EPI 序列、对比噪声比高于单激发 EPI-STIR,但测得的 ADC 值可更高。

研究设计与样本

  • 研究纳入 65 名参与者,在 3T 下采集单激发 EPI-STIR、单激发 EPI-频谱预饱和反转恢复和多激发 EPI-频谱预饱和反转恢复 3 种头颈部 DWI 序列,由 2 名独立阅片者对多个解剖区域进行 5 分视觉评分,并由 1 名阅片者测量对比噪声比和 ADC。

关键影像表现/征象

  • 单激发 EPI-STIR 的脂肪抑制均匀性视觉评分除眶部外均高于其他序列(P < .05)。
  • 多激发 EPI-频谱预饱和反转恢复的图像变形视觉评分在所有区域均高于单激发 EPI 序列(P < .001)。
  • 单激发 EPI-STIR 的对比噪声比多数低于其他序列(P < .001)。
  • 多激发 EPI-频谱预饱和反转恢复的 ADC 值显著高于单激发 EPI 序列(P ≤ .001)。

诊断标准与关键数值

  • 脂肪抑制均匀性和图像变形采用 5 分视觉评分,由 2 名独立阅片者在多个解剖区域评估。
  • 对比噪声比和 ADC 由 1 名阅片者测量。

临床应用与阅片要点

  • 作者认为多激发 EPI-频谱预饱和反转恢复整体图像质量最佳,脂肪抑制相对均匀、变形较小、对比噪声比高于单激发 EPI-STIR。
  • 作者指出多激发 EPI-频谱预饱和反转恢复测得的 ADC 值可更高,将既往报道的 ADC 值用于临床时需谨慎。

局限性

  • 作者指出多激发 EPI-频谱预饱和反转恢复测得的 ADC 值可更高,将既往报道的 ADC 值用于临床时需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: DWI of the head and neck can reveal valuable information, but the effects of fat suppression and multishot acquisition on image quality have not been thoroughly investigated. We aimed to comprehensively compare the quality of head and neck DWI at 3T using 2 fat-suppression techniques, STIR, and spectral presaturation with inversion recovery, which were used with both single- and multishot EPI.

MATERIALS AND METHODS: Sixty-five study participants underwent 3 DWI sequences of single-shot EPI-STIR, single-shot EPI-spectral presaturation with inversion recovery, and multishot EPI-spectral presaturation with inversion recovery of the head and neck. In multiple anatomic regions, 2 independent readers assessed 5-point visual scores for fat-suppression uniformity and image distortion, and 1 reader measured the contrast-to-noise ratio and ADC.

RESULTS: The mean visual score for fat-suppression uniformity was higher in single-shot EPI-STIR than in other sequences (all regions except for the orbital region, P < .05). The mean visual score for image distortion was higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (all regions, P < .001). Contrast-to-noise ratio was mostly lower in single-shot EPI-STIR than in other sequences (P < .001), and ADC was significantly higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (P ≤ .001).

CONCLUSIONS: Overall, multishot EPI-spectral presaturation with inversion recovery provided the best image quality, with relatively homogeneous fat suppression, less image distortion than single-shot EPI sequences, and higher contrast-to-noise ratio than single-shot EPI-STIR. The measured ADC values can be higher in multishot EPI-spectral presaturation with inversion recovery, which necessitates cautious application of the previously reported ADC values to clinical settings.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。