文献速递神经MR

高分辨率血管壁MR成像鉴别大脑中动脉供血区深部皮质下梗死

Differentiation of Deep Subcortical Infarction Using High-Resolution Vessel Wall MR Imaging of Middle Cerebral Artery.
PubMed 文献 · Korean J Radiol · 2017-09-21

回顾性纳入2009年7月至2012年2月145例深部皮质下梗死患者(纹状体囊梗死81例、豆纹动脉梗死64例),分析大脑中动脉狭窄程度及斑块特征。纹状体囊梗死组大脑中动脉狭窄更重、斑块更常见且范围更大、T2高信号及斑块强化更多;两组斑块偏心性和位置无显著差异。高分辨率血管壁成像可能有助于区分两种梗死的病理生理机制。

要点

  • 纹状体囊梗死大脑中动脉狭窄程度较豆纹动脉梗死更重(p=0.040)。
  • 纹状体囊梗死大脑中动脉斑块更常见(p=0.028)、范围更大(p=0.001)。
  • 纹状体囊梗死斑块T2高信号(p=0.001)及强化(p=0.002)更多。

核心结论

  • 纹状体囊梗死与豆纹动脉梗死的大脑中动脉斑块高分辨率血管壁成像表现相似,但纹状体囊梗死斑块更常见、更大且T2高信号和强化更多,提示高分辨率血管壁成像可能有助于区分两者潜在的病理生理机制。

研究设计与样本

  • 回顾性研究,经机构审查委员会批准并豁免知情同意,纳入2009年7月至2012年2月145例连续深部皮质下梗死患者(纹状体囊梗死81例、豆纹动脉梗死64例),均行大脑中动脉高分辨率血管壁成像,采用Fisher精确检验比较两组。

关键影像表现/征象

  • 纹状体囊梗死组大脑中动脉狭窄程度较豆纹动脉梗死组更重(p=0.040)。
  • 纹状体囊梗死组大脑中动脉斑块较豆纹动脉梗死组更常见(p=0.028)。
  • 纹状体囊梗死组斑块范围较豆纹动脉梗死组更大(p=0.001)。
  • 纹状体囊梗死组斑块T2高信号较豆纹动脉梗死组更多(p=0.001)。
  • 纹状体囊梗死组斑块强化较豆纹动脉梗死组更多(p=0.002)。

诊断标准与关键数值

  • 斑块偏心性和位置在纹状体囊梗死与豆纹动脉梗死两组间无显著差异。

临床应用与阅片要点

  • 作者认为高分辨率血管壁成像可能有助于辅助区分纹状体囊梗死与豆纹动脉梗死潜在的病理生理机制。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the utility of high-resolution vessel wall imaging (HR-VWI) of middle cerebral artery (MCA), and to compare HR-VWI findings between striatocapsular infarction (SC-I) and lenticulostriate infarction (LS-I).

MATERIALS AND METHODS: This retrospective study was approved by the Institutional Review Board, and informed consent was waived. From July 2009 to February 2012, 145 consecutive patients with deep subcortical infarctions (SC-I, n = 81; LS-I, n = 64) who underwent HR-VWI were included in this study. The degree of MCA stenosis and the characteristics of MCA plaque (presence, eccentricity, location, extent, T2-high signal intensity [T2-HSI], and plaque enhancement) were analyzed, and compared between SC-I and LS-I, using Fisher's exact test.

RESULTS: Stenosis was more severe in SC-I than in LS-I (p = 0.040). MCA plaque was more frequent in SC-I than in LS-I (p = 0.028), having larger plaque extent (p = 0.001), more T2-HSI (p = 0.001), and more plaque enhancement (p = 0.002). The eccentricity and location of the plaque showed no significant difference between the two groups.

CONCLUSION: Both SC-I and LS-I have similar HR-VWI findings of the MCA plaque, but SC-I had more frequent, larger plaques with greater T2-HSI and enhancement. This suggests that HR-VWI may have a promising role in assisting the differentiation of underlying pathophysiological mechanism between SC-I and LS-I.