文献速递神经介入DSA

血流导向支架治疗颅内分叉部动脉瘤后血流动力学在分叉动脉中的作用

The Role of Hemodynamics in Intracranial Bifurcation Arteries after Aneurysm Treatment with Flow-Diverter Stents.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-11-23

研究纳入25例血流导向支架治疗的颅内分叉部动脉瘤患者,结合影像与计算流体动力学分析,发现分叉不对称(直径比<0.7)与支架置入后载瘤动脉远端血管管径改变显著相关(P<.001),不对称分叉(直径比<0.65)置入支架时被覆盖血管壁面剪切应力受影响最大。

要点

  • 分叉不对称(直径比<0.7)与血流导向支架术后血管管径改变显著相关(P<.001)。
  • 出现狭窄或亚急性闭塞的病例对称比更低(子血管直径比中位数0.59 vs 管径保持者0.95)。
  • 不对称分叉(直径比<0.65)置入支架时被覆盖血管壁面剪切应力受影响最大。

核心结论

  • 解剖数据分析显示血管管径改变与以直径比<0.7为特征的分叉不对称之间存在统计学显著对应关系(P<.001);计算流体动力学结果显示不对称分叉(直径比<0.65)置入血流导向支架时血流动力学受影响最大,壁面剪切应力场有明显改变;需进一步研究和临床验证以明确支架术后血管管径改变的全部相关因素。

研究设计与样本

  • 研究纳入25例接受血流导向支架治疗的分叉部动脉瘤患者,获取影像学图像与人口统计学数据;采用箱线图与Mann-Whitney秩和检验评估解剖数据与管径改变的关系;在理想化与患者特异性解剖模型上进行计算流体动力学分析。

关键影像表现/征象

  • 出现狭窄或亚急性闭塞的病例对称比更低,子血管直径比中位数为0.59,而治疗后管径保持的病例为0.95。
  • 计算流体动力学分析显示,在不对称分叉(直径比<0.65)置入血流导向支架时,被覆盖血管的壁面剪切应力受影响更大;在对称解剖(直径比约1.00)置入时受影响较小。

诊断标准与关键数值

  • 对称/不对称定义为直径比1为对称、直径比<1为不对称。
  • 血管管径改变与分叉不对称(直径比<0.7)相关,P<.001。
  • 计算流体动力学分析中,不对称分叉以直径比<0.65为界,对称解剖以直径比约1.00为界。

临床应用与阅片要点

  • 阅片时可测量分叉部子血管直径比,评估分叉对称性,不对称(直径比<0.7)者术后需关注被覆盖血管管径改变。
  • 出现狭窄或亚急性闭塞的病例子血管直径比中位数为0.59,管径保持者为0.95,提示对称性可作为随访观察的参考指标。

局限性

  • 原文指出需进一步研究和临床验证以明确血流导向支架术后血管管径改变的全部相关因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Treatment of intracranial bifurcation aneurysms with flow-diverter stents can lead to caliber changes of the distal vessels in a subacute phase. This study aims to evaluate whether local anatomy and flow disruption induced by flow-diverter stents are associated with vessel caliber changes in intracranial bifurcations.

MATERIALS AND METHODS: Radiologic images and demographic data were acquired for 25 patients with bifurcation aneurysms treated with flow-diverter stents. Whisker plots and Mann-Whitney rank sum tests were used to evaluate if anatomic data and caliber changes could be linked. Symmetry/asymmetry were defined as diameter ratio 1 = symmetric and diameter ratio <1 = asymmetric. Computational fluid dynamics was performed on idealized and patient-specific anatomies to evaluate flow changes induced by flow-diverter stents in the jailed vessel.

RESULTS: Statistical analysis identified a marked correspondence between asymmetric bifurcation and caliber change. Symmetry ratios were lower for cases showing narrowing or subacute occlusion (medium daughter vessel diameter ratio = 0.59) compared with cases with posttreatment caliber conservation (medium daughter vessel diameter ratio = 0.95). Computational fluid dynamics analysis in idealized and patient-specific anatomies showed that wall shear stress in the jailed vessel was more affected when flow-diverter stents were deployed in asymmetric bifurcations (diameter ratio <0.65) and less affected when deployed in symmetric anatomies (diameter ratio ∼1.00).

CONCLUSIONS: Anatomic data analysis showed statistically significant correspondence between caliber changes and bifurcation asymmetry characterized by diameter ratio <0.7 (P < .001). Similarly, computational fluid dynamics results showed the highest impact on hemodynamics when flow-diverter stents are deployed in asymmetric bifurcations (diameter ratio <0.65) with noticeable changes on wall sheer stress fields. Further research and clinical validation are necessary to identify all elements involved in vessel caliber changes after flow-diverter stent procedures.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Narata AP, de Moura FS, Larrabide I, et al. The Role of Hemodynamics in Intracranial Bifurcation Arteries after Aneurysm Treatment with Flow-Diverter Stents. AJNR Am J Neuroradiol. 2017. PMID: 29170270. doi:10.3174/ajnr.A5471

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。