基于MR图像影像组学特征区分伽玛刀放射外科治疗后放射性坏死与肿瘤进展的预测模型
回顾性纳入87例经病理确诊的脑转移瘤患者(坏死24个病灶、进展73个病灶),从4个MR序列(T1、T1增强、T2、FLAIR)两个随访时间点提取285个影像组学特征。基于T1增强和T2图像的五特征组合及delta影像组学结合RUSBoost集成分类器,在留一交叉验证中总体预测准确率73.2%、AUC 0.73。
要点
- T1增强联合T2图像的五项影像组学特征有助于区分放射性坏死与肿瘤进展。
- delta影像组学特征结合RUSBoost分类器留一交叉验证准确率73.2%、AUC 0.73。
- 部分影像组学特征在进展病灶中的可重复性优于坏死病灶。
核心结论
- 从MR图像提取的delta影像组学特征有潜力区分脑转移瘤放射外科治疗后的放射性坏死与肿瘤进展。
研究设计与样本
- 回顾性研究,纳入87例经病理确诊的脑转移瘤患者(坏死24个病灶、进展73个病灶),从每例患者每个病灶两个随访时间点获取的T1、T1增强、T2和FLAIR四个MR序列计算285个影像组学特征。
诊断标准与关键数值
- 基于T1增强和T2图像的五项影像组学特征组合用于区分坏死与进展病灶;delta影像组学特征结合RUSBoost集成分类器在留一交叉验证中总体预测准确率73.2%、AUC 0.73。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop a model using radiomic features extracted from MR images to distinguish radiation necrosis from tumour progression in brain metastases after Gamma Knife radiosurgery.
METHODS: We retrospectively identified 87 patients with pathologically confirmed necrosis (24 lesions) or progression (73 lesions) and calculated 285 radiomic features from four MR sequences (T1, T1 post-contrast, T2, and fluid-attenuated inversion recovery) obtained at two follow-up time points per lesion per patient. Reproducibility of each feature between the two time points was calculated within each group to identify a subset of features with distinct reproducible values between two groups. Changes in radiomic features from one time point to the next (delta radiomics) were used to build a model to classify necrosis and progression lesions.
RESULTS: A combination of five radiomic features from both T1 post-contrast and T2 MR images were found to be useful in distinguishing necrosis from progression lesions. Delta radiomic features with a RUSBoost ensemble classifier had an overall predictive accuracy of 73.2% and an area under the curve value of 0.73 in leave-one-out cross-validation.
CONCLUSIONS: Delta radiomic features extracted from MR images have potential for distinguishing radiation necrosis from tumour progression after radiosurgery for brain metastases.
KEY POINTS: • Some radiomic features showed better reproducibility for progressive lesions than necrotic ones • Delta radiomic features can help to distinguish radiation necrosis from tumour progression • Delta radiomic features had better predictive value than did traditional radiomic features.
引用
- Zhang Z, Yang J, Ho A, et al. A predictive model for distinguishing radiation necrosis from tumour progression after gamma knife radiosurgery based on radiomic features from MR images. Eur Radiol. 2017. PMID: 29178031. doi:10.1007/s00330-017-5154-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。