美国放射学会适宜性标准®:耳鸣
美国放射学会(ACR)基于循证医学方法(RAND/UCLA适宜性方法和GRADE)制定耳鸣影像检查适宜性标准。病史与体格检查是决定是否需要影像检查的关键第一步。搏动性耳鸣可用CT和MRI评估血管异常;伴不对称听力损失、神经功能缺损或头部外伤时,影像检查应遵循相应ACR适宜性标准文档。主观非搏动性且不定位单侧的耳鸣通常不适合影像检查。
要点
- 病史和体格检查是决定耳鸣患者是否需要影像检查的关键第一步。
- 搏动性耳鸣可用CT和MRI评估潜在血管异常或异常。
- 主观、非搏动性且不定位单侧的耳鸣通常不适合影像检查。
核心结论
- 搏动性耳鸣可用CT和MRI评估潜在血管异常;伴不对称听力损失、神经功能缺损或头部外伤时,影像检查应遵循相应ACR适宜性标准文档;主观、非搏动性且不定位单侧的耳鸣通常不适合影像检查。
研究设计与样本
- 美国放射学会(ACR)适宜性标准,由多学科专家小组每年审查,制定与修订包括对同行评审期刊当前医学文献的广泛分析,并应用RAND/UCLA适宜性方法和GRADE对特定临床场景的影像和治療程序适宜性进行评级;证据缺乏或模棱两可时,专家意见可补充现有证据。
诊断标准与关键数值
- 搏动性耳鸣:CT和MRI可用于评估潜在血管异常或异常。
- 伴不对称听力损失、神经功能缺损或头部外伤:影像检查应遵循相应ACR适宜性标准文档,而非依据耳鸣本身。
- 主观、非搏动性且不定位单侧的耳鸣:影像检查通常不适合。
临床应用与阅片要点
- 病史和体格检查是决定耳鸣患者是否需要影像检查的关键第一步。
- 搏动性耳鸣可考虑CT和MRI评估血管异常。
- 伴不对称听力损失、神经功能缺损或头部外伤时,应遵循相应ACR适宜性标准文档选择影像检查。
- 主观、非搏动性且不定位单侧的耳鸣通常不适合影像检查。
局限性
- 证据缺乏或模棱两可时,专家意见可补充现有证据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Tinnitus is the perception of sound in the absence of an external source. It is a common symptom that can be related to hearing loss and other benign causes. However, tinnitus may be disabling and can be the only symptom in a patient with a central nervous system process disorder. History and physical examination are crucial first steps to determine the need for imaging. CT and MRI are useful in the setting of pulsatile tinnitus to evaluate for an underlying vascular anomaly or abnormality. If there is concomitant asymmetric hearing loss, neurologic deficit, or head trauma, imaging should be guided by those respective ACR Appropriateness Criteria® documents, rather than the presence of tinnitus. Imaging is not usually appropriate in the evaluation of subjective, nonpulsatile tinnitus that does not localize to one ear. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
引用
- Kessler MM, Moussa M, Bykowski J, et al. ACR Appropriateness Criteria® Tinnitus. J Am Coll Radiol. 2017. PMID: 29101995. doi:10.1016/j.jacr.2017.08.052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。