单源CT全身扫描中100 kVp结合正弦图确认迭代重建算法对降低辐射与对比剂剂量的价值:一项个体内可行性研究
该回顾性个体内研究纳入43例肿瘤患者,比较120 kVp与100 kVp联合SAFIRE协议在全身CT中的表现。100 kVp协议使SSDE降低34%、碘负荷降低21%,且100 kVp-S的图像质量相似或更优。
要点
- 100 kVp联合SAFIRE可在维持图像质量的同时显著降低辐射与对比剂剂量。
- 100 kVp协议SSDE为10.6±1.1 mGy,较120 kVp的16.1±1.8 mGy降低34%。
- 100 kVp协议碘负荷为24.8±4 g,较120 kVp的31.5±5.5 g降低21%(p<0.01)。
核心结论
- 与120 kVp协议相比,100 kVp联合SAFIRE在肿瘤评估全身CT中可大幅降低对比剂和辐射剂量,同时维持图像质量。
研究设计与样本
- 回顾性个体内可行性研究,纳入43例在不同时间点接受120 kVp和100 kVp协议全身CT(胸-腹-盆CT)的肿瘤患者,平均扫描间隔98天;120 kVp图像采用滤波反投影(FBP)重建,100 kVp图像分别采用FBP(100 kVp-F)和SAFIRE(100 kVp-S)重建;比较各协议的体型特异性剂量估算(SSDE)、碘负荷和图像质量。
诊断标准与关键数值
- 100 kVp协议对比剂剂量为480 mg碘/kg,120 kVp协议为600 mg碘/kg。
- 100 kVp协议SSDE为10.6±1.1 mGy,120 kVp协议为16.1±1.8 mGy,100 kVp协议降低34%。
- 100 kVp协议碘负荷为24.8±4 g,120 kVp协议为31.5±5.5 g,100 kVp协议降低21%(p<0.01)。
- 100 kVp-S的对比增强、客观图像噪声、对比噪声比和视觉评分与120 kVp协议相似或更优。
临床应用与阅片要点
- 在肿瘤患者全身CT中,采用100 kVp联合SAFIRE可在维持图像质量的同时降低辐射和对比剂剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To perform an intra-individual investigation of the usefulness of a contrast medium (CM) and radiation dose-reduction protocol using single-source computed tomography (CT) combined with 100 kVp and sinogram-affirmed iterative reconstruction (SAFIRE) for whole-body CT (WBCT; chest-abdomen-pelvis CT) in oncology patients.
MATERIALS AND METHODS: Forty-three oncology patients who had undergone WBCT under both 120 and 100 kVp protocols at different time points (mean interscan intervals: 98 days) were included retrospectively. The CM doses for the 120 and 100 kVp protocols were 600 and 480 mg iodine/kg, respectively; 120 kVp images were reconstructed with filtered back-projection (FBP), whereas 100 kVp images were reconstructed with FBP (100 kVp-F) and the SAFIRE (100 kVp-S). The size-specific dose estimate (SSDE), iodine load and image quality of each protocol were compared.
RESULTS: The SSDE and iodine load of 100 kVp protocol were 34% and 21%, respectively, lower than of 120 kVp protocol (SSDE: 10.6±1.1 versus 16.1±1.8 mGy; iodine load: 24.8±4versus 31.5±5.5 g iodine, p<0.01). Contrast enhancement, objective image noise, contrast-to-noise-ratio, and visual score of 100 kVp-S were similar to or better than of 120 kVp protocol.
CONCLUSION: Compared with the 120 kVp protocol, the combined use of 100 kVp and SAFIRE in WBCT for oncology assessment with an SSCT facilitated substantial reduction in the CM and radiation dose while maintaining image quality.
引用
- Nagayama Y, Nakaura T, Oda S, et al. Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study. Clin Radiol. 2017. PMID: 29029768. doi:10.1016/j.crad.2017.09.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。