不同狭窄组中斑块回声、厚度与新生血管关系的定量与半定量超声造影评估
研究纳入224个颈动脉粥样硬化斑块,按狭窄程度分为轻度(<50%;135个,60.27%)、中度(50%-69%;39个,17.41%)和重度(70%-99%;50个,22.32%)三组,用定量与半定量超声造影评估斑块新生血管,分析其与斑块回声、厚度的关系。结果显示两种方法在评估新生血管与回声、厚度关系上等效,但定量法因运动伪影对<3.5 mm斑块可能失败。
要点
- 定量与半定量超声造影在评估斑块新生血管与回声、厚度关系上等效。
- 轻度狭窄组中,曲线下面积比值(RAUC)与斑块厚度呈负相关(r=-0.317,p=0.001)。
- 定量法因运动伪影对厚度<3.5 mm的斑块可能失败。
核心结论
- 定量与半定量超声造影在评估斑块新生血管与回声、厚度关系上等效,但定量法因运动伪影对<3.5 mm斑块可能失败。
研究设计与样本
- 研究纳入224个颈动脉粥样硬化斑块,按狭窄程度分为轻度(<50%;135个,60.27%)、中度(50%-69%;39个,17.41%)和重度(70%-99%;50个,22.32%)三组,采用定量与半定量超声造影评估斑块新生血管。
诊断标准与关键数值
- 轻度狭窄组中,曲线下面积比值(RAUC)与斑块厚度呈负相关(r=-0.317,p=0.001)。
- 轻度狭窄组按斑块厚度四分位分组,1.5-2.2 mm组与≥3.5 mm组差异显著(p=0.002),2.3-2.8 mm组与≥3.5 mm组差异显著(p<0.001),2.9-3.4 mm组与≥3.5 mm组差异显著(p<0.001)。
临床应用与阅片要点
- 定量与半定量超声造影均可用于评估斑块新生血管与回声、厚度的关系。
- 定量法因运动伪影对厚度<3.5 mm的斑块可能失败。
局限性
- 定量方法因运动伪影对<3.5 mm的斑块可能失败。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of this study was to determine the relationship between plaque echo, thickness and neovascularization in different stenosis groups using quantitative and semi-quantitative contrast-enhanced ultrasound (CEUS) in patients with carotid atherosclerosis plaque. A total of 224 plaques were divided into mild stenosis (<50%; 135 plaques, 60.27%), moderate stenosis (50%-69%; 39 plaques, 17.41%) and severe stenosis (70%-99%; 50 plaques, 22.32%) groups. Quantitative and semi-quantitative methods were used to assess plaque neovascularization and determine the relationship between plaque echo, thickness and neovascularization. Correlation analysis revealed no relationship of neovascularization with plaque echo in the groups using either quantitative or semi-quantitative methods. Furthermore, there was no correlation of neovascularization with plaque thickness using the semi-quantitative method. The ratio of areas under the curve (RAUC) was negatively correlated with plaque thickness (r = -0.317, p = 0.001) in the mild stenosis group. With the quartile method, plaque thickness of the mild stenosis group was divided into four groups, with significant differences between the 1.5-2.2 mm and ≥3.5 mm groups (p = 0.002), 2.3-2.8 mm and ≥3.5 mm groups (p <0.001) and 2.9-3.4 mm and ≥3.5 mm groups (p <0.001). Both semi-quantitative and quantitative CEUS methods characterizing neovascularization of plaque are equivalent with respect to assessing relationships between neovascularization, echogenicity and thickness. However, the quantitative method could fail for plaque <3.5 mm because of motion artifacts.
引用
- Song Y, Feng J, Dang Y, et al. Relationship between Plaque Echo, Thickness and Neovascularization Assessed by Quantitative and Semi-quantitative Contrast-Enhanced Ultrasonography in Different Stenosis Groups. Ultrasound Med Biol. 2017. PMID: 28965720. doi:10.1016/j.ultrasmedbio.2017.08.1882
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。