文献速递外周血管技术与安全US

长超声视频序列中颈动脉横切面的分析

Analysis of Carotid Artery Transverse Sections in Long Ultrasound Video Sequences.
PubMed 文献 · Ultrasound Med Biol · 2017-10-12

该文提出一种视频处理方法,用于颈动脉横切面的自动几何分析,通过补偿全局运动和特征漂移,在任意长度超声序列中可靠估计动脉壁运动。方法采用改进Viola-Jones检测器和Hough变换定位动脉,识别优势散射体(兴趣点)并用金字塔Lucas-Kanade法追踪。使用Harris检测器时,模拟序列平均均方根误差为2.16±1.18像素,运行时间约30-70毫秒/帧(空间分辨率达490×490像素)。

要点

  • 方法可自动分析颈动脉横切面超声视频中的动脉壁运动。
  • 通过检测全局运动和兴趣点重初始化,提高对全局运动和特征漂移的鲁棒性。
  • 使用Harris检测器时模拟序列平均均方根误差为2.16±1.18像素。

核心结论

  • 所提出的视频处理方法能在任意长度超声序列中可靠、准确地估计动脉壁运动,在现有方法失败或不准确的情况下仍有效。

研究设计与样本

  • 研究提出并评估一种视频处理算法,使用模拟和真实超声视频序列进行性能评价,未报告样本量、中心数及具体设备型号。

诊断标准与关键数值

  • 使用Harris检测器进行兴趣点检测时,所有模拟序列的平均均方根误差为2.16±1.18像素。
  • 运行时间约30-70毫秒/帧,适用于空间分辨率达490×490像素的序列。

局限性

  • 作者预期该方法在未来临床实践中将有助于动脉粥样硬化和其他心血管疾病的非侵入性早期诊断,尚未在临床实践中验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Examination of the common carotid artery (CCA) based on an ultrasound video sequence is an effective method for detecting cardiovascular diseases. Here, we propose a video processing method for the automated geometric analysis of CCA transverse sections. By explicitly compensating the parasitic phenomena of global movement and feature drift, our method enables a reliable and accurate estimation of the movement of the arterial wall based on ultrasound sequences of arbitrary length and in situations where state-of-the-art methods fail or are very inaccurate. The method uses a modified Viola-Jones detector and the Hough transform to localize the artery in the image. Then it identifies dominant scatterers, also known as interest points (IPs), whose positions are tracked by means of the pyramidal Lucas-Kanade method. Robustness to global movement and feature drift is achieved by a detection of global movement and subsequent IP re-initialization, as well as an adaptive removal and addition of IPs. The performance of the proposed method is evaluated using simulated and real ultrasound video sequences. Using the Harris detector for IP detection, we obtained an overall root-mean-square error, averaged over all the simulated sequences, of 2.16 ± 1.18 px. The computational complexity of our method is compatible with real-time operation; the runtime is about 30-70 ms/frame for sequences with a spatial resolution of up to 490 × 490 px. We expect that in future clinical practice, our method will be instrumental for non-invasive early-stage diagnosis of atherosclerosis and other cardiovascular diseases.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Říha K, Zukal M, Hlawatsch F, et al. Analysis of Carotid Artery Transverse Sections in Long Ultrasound Video Sequences. Ultrasound Med Biol. 2017. PMID: 29031984. doi:10.1016/j.ultrasmedbio.2017.08.933

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。