放射科医师培训级别与治疗性髋关节注射辐射暴露的关系
该研究回顾性分析2012年8月1日至2015年5月30日间1362例透视引导髋关节注射,按操作医师培训级别分组,比较透视时间(FT)和剂量面积乘积(DAP),混合效应模型显示各组间FT(p=0.31)和DAP(p=0.82)均无统计学显著差异,结论为放射科医师培训级别与患者辐射暴露无关联。
要点
- 透视引导髋关节注射中,住院医师各年级与专科医师组间透视时间无统计学显著差异(p=0.31)。
- 各组间剂量面积乘积无统计学显著差异(p=0.82),提示培训级别不影响患者辐射暴露。
- 住院医师操作时患者辐射暴露水平与经验更丰富的同事相当。
核心结论
- 放射科医师培训级别与透视引导髋关节注射中患者辐射暴露(FT和DAP)无关联;住院医师操作时辐射暴露水平与经验更丰富的同事相当。
研究设计与样本
- 经IRB批准的回顾性审查,检索本机构放射科报告数据库,纳入2012年8月1日至2015年5月30日间所有透视引导髋关节注射,共1362例符合纳入标准;按操作时培训级别分为R1(20名)、R2(19名)、R3(18名)、R4(20名)、非肌骨放射科医师组(5名)和肌骨专科培训放射科医师组(7名);采用混合效应模型,以培训级别为独立预测因子分别建模FT和DAP。
诊断标准与关键数值
- 总体平均FT为26秒(±17SD),总体平均DAP为20.4uGy*m2(±22.3SD);混合效应模型显示各组间FT无统计学显著差异(p=0.31),DAP无统计学显著差异(p=0.82)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to determine the relationship between the level of training of the performing radiologist and patient radiation exposure, as measured by fluoroscopy time (FT) and dose area product (DAP), during fluoroscopic guided hip injections.
MATERIALS AND METHODS: This IRB-approved retrospective review of our institutional radiology report database identified all fluoroscopic guided hip injections performed between August 1st, 2012 and May 30th, 2015. Performing radiologists were divided into groups based on their level of training at the time of the procedure: first-year residents (R1), second-year residents (R2), third-year residents (R3), fourth-year residents (R4), staff fellowship trained musculoskeletal radiologists, and non-musculoskeletal radiologists. A mixed effects model was applied, using level of training as an independent predictor to model FT and DAP separately.
RESULTS: There were 20, 19, 18 and 20 residents in the R1, R2, R3 and R4 groups, respectively. There were 5 performers in the non-MSK radiologist group, and 7 in the MSK radiologist group. A total of 1362 hip injection procedures met the inclusion criteria and were included in the analysis. The overall average FT was 26s (±17SD) and overall average DAP was 20.4uGy*m2 (±22.3SD). The mixed effects model showed no statistically significant difference between the groups, for FT (p=0.31) and for DAP (p=0.82).
CONCLUSION: There is no association between radiologist level of training and patient radiation exposure for fluoroscopic hip injections. Resident trainees maintain radiation exposure to patients at levels comparable to their more experienced colleagues.
引用
- Sanders BSP, McInnes MDF, Sampaio ML, et al. Relationship between radiologist training level and radiation exposure for therapeutic hip injections. Eur J Radiol. 2017. PMID: 28987659. doi:10.1016/j.ejrad.2017.07.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。