术前超声评估前骨盆平面用于个性化全髋关节置换术
该研究提出一种基于超声和移动设备的无创方法,在43例拟行全髋关节置换术的患者中术前测量前骨盆平面方向,证实骨盆方向在仰卧位和站立位均存在很大变异性,并讨论其对髋臼杯最终位置的影响及个性化放置的实用解决方案,包括基于手术台倾斜的自有方法。
要点
- 术前超声可无创测量前骨盆平面方向,不干扰手术流程。
- 骨盆方向在仰卧位和站立位均存在很大变异性。
- 常用髋臼杯植入指南仅适用于小部分人群,多数需按个体解剖调整。
核心结论
- 当前常用的髋臼杯植入指南只能有效适用于小部分人群,多数情况下必须根据患者个体解剖重新调整髋臼杯方向。
研究设计与样本
- 研究纳入43例拟行全髋关节置换术的患者,采用基于超声和移动设备的新开发无创方法测量前骨盆平面方向。
关键影像表现/征象
- 前骨盆平面方向在仰卧位和站立位均表现出很大变异性。
- 骨盆方向的变异性会影响髋臼杯的最终位置。
临床应用与阅片要点
- 作者提出基于手术台倾斜的个性化髋臼杯放置方法。
- 作者探讨了若干个性化髋臼杯放置的实用解决方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Correct positioning of the acetabular component is a key factor in minimizing the risk of dislocation after total hip replacement (THR) surgery. A "safe" orientation of the cup is usually defined by 2 angles measured between its geometric axis and the anterior pelvic plane. However, in the current state-of-the-art approach to THR surgery, the intraoperative orientation of the anterior pelvic plane cannot be measured. Even less is known about the functional orientation of the pelvis, which determines the postoperative orientation of the cup during the patient's everyday activities. The aim of this article is to present an original approach to personalized THR surgery, in which the necessary measurements are done preoperatively without interfering with the surgical work flow, and the individual orientation of the cup is obtained without navigation using standard tools that are available in the operating room.
METHODS: To quantify the effect of the anatomic conditions on the final orientation of the cup, we measured the orientation of the anterior pelvic plane in 43 patients scheduled for THR using a newly developed noninvasive method based on ultrasonography and mobile devices.
RESULTS: Our results confirm a large variability of the pelvic orientation in both supine and standing positions. We further show how this variability affects the final position of the cup and discuss its consequences for the patient. Finally, we explore a few practical solutions for individualized cup placement, including our own approach, which is based on tilting of the operating table.
CONCLUSIONS: In this work, we show that the common guidelines used today for cup implantation can only be effectively applied to a small portion of the population. In most cases, it is crucial that the orientation of the cup is readjusted for the particular anatomy of the individual patient.
引用
- Kochman A, Goral A, Kozak J, et al. Preoperative Ultrasonographic Assessment of the Anterior Pelvic Plane for Personalized Total Hip Replacement. J Ultrasound Med. 2017. PMID: 29027688. doi:10.1002/jum.14431
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。