本研究用25 MHz高频超声体外检查33个取自晚期膝骨关节炎患者的圆柱形骨软骨盘,观察潮线形态并与显微CT对照,发现两者形态对应良好;潮线超声粗糙度指数与软骨下板及下方骨小梁的骨体积分数和骨密度均呈负相关。

要点

  • 高频超声显示的潮线形态与显微CT所见对应良好。
  • 潮线超声粗糙度指数越高,软骨下板及骨小梁骨体积分数和骨密度越低。
  • 高频超声有望在评估软骨之外同时评估软骨下骨改变。

核心结论

  • 本初步研究显示高频超声所测形态可反映软骨下骨质量,高频超声是评估骨关节炎中软骨下骨改变的有前景的影像工具。

研究设计与样本

  • 体外研究,采用25 MHz高频超声检查取自晚期膝骨关节炎患者的圆柱形骨软骨盘33个,以显微CT为参照,用Spearman相关系数分析潮线超声粗糙度指数与骨质量指标的关系。

关键影像表现/征象

  • 高频超声所见的潮线形态与显微CT观察结果对应良好。
  • 潮线超声粗糙度指数由原始射频信号导出,用于与显微CT测量的骨质量指标比较。

诊断标准与关键数值

  • 潮线超声粗糙度指数与软骨下板骨体积分数呈负相关(ρ=-0.73,p<0.001)。
  • 潮线超声粗糙度指数与软骨下板骨密度呈负相关(ρ=-0.40,p=0.020)。
  • 潮线超声粗糙度指数与下方骨小梁骨体积分数呈负相关(ρ=-0.39,p=0.025)。
  • 潮线超声粗糙度指数与下方骨小梁骨密度呈负相关(ρ=-0.43,p=0.012)。

临床应用与阅片要点

  • 作者认为高频超声是评估骨关节炎软骨下骨改变的有前景的影像工具。

局限性

  • 原文称本研究为初步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

High-frequency ultrasound imaging has been widely adopted for assessment of the degenerative changes of articular cartilage in osteoarthritis (OA). Yet, there are few reports on investigating its capability to evaluate subchondral bone. Here, we employed high-frequency ultrasound imaging (25 MHz) to examine in vitro the tidemark in cylindrical osteochondral disks (n = 33) harvested from advanced OA knees of humans. We found good correspondence in morphology observed by ultrasound imaging and micro-computed tomography. Ultrasound roughness index (URI) of tidemark was derived from the raw radiofrequency signals to compare with bone quality factors, including bone volume fraction (BV/TV) and bone mineral density (BMD) measured by micro-computed tomography, using the Spearman correlation (ρ). URI of the tidemark was negatively associated with the subchondral plate BV/TV (ρ = -0.73, p <0.001), BMD (ρ = -0.40, p = 0.020), as well as the underneath trabecular bone BV/TV (ρ = -0.39, p = 0.025) and BMD (ρ = -0.43, p = 0.012). In conclusion, this preliminary study demonstrated that morphology measured by high-frequency ultrasound imaging could reflect the quality of the subchondral bone. High-frequency ultrasound is a promising imaging tool to evaluate the changes of the subchondral bone in addition to those of the overlying cartilage in OA.