文献速递儿科影像头颈甲状腺与浅表US

儿童甲状腺癌超声可检出强回声灶的模式及其对应组织病理学:一项观察性研究

Patterns of Sonographically Detectable Echogenic Foci in Pediatric Thyroid Carcinoma with Corresponding Histopathology: An Observational Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-10-26

回顾性分析15个经病理证实的儿童恶性甲状腺结节的超声,按ACR TI-RADS将强回声灶分为4种形态模式并评估观察者间一致性;点状强回声灶见于全部结节,但仅27%病理为砂粒体钙化,60%为间质钙化、53%为黏稠胶质。

要点

  • 儿童恶性甲状腺结节中,点状强回声灶最常见,全部15个结节均可见。
  • 超声强回声灶多数不代表砂粒体钙化:仅4/15(27%)病理见砂粒体。
  • 9/15(60%)见间质钙化、8/15(53%)见黏稠胶质,可表现为强回声灶。

核心结论

  • 儿童恶性甲状腺结节的超声强回声灶可按ACR TI-RADS可靠分类,点状强回声灶为最常见亚型。
  • 这些强回声灶多数并非砂粒体钙化,超过半数的恶性结节含间质钙化或黏稠胶质。

研究设计与样本

  • 回顾性观察性研究,纳入15个经病理证实的儿童恶性甲状腺结节。
  • 由2名放射科医生独立阅片,按ACR TI-RADS的4种强回声灶形态模式分类并记录存在与分布,分歧经共识解决。
  • 对照甲状腺切除术标本的组织病理学,评估砂粒体钙化、营养不良性/间质钙化及嗜酸性/黏稠胶质的存在与分布。

关键影像表现/征象

  • 点状强回声灶见于全部结节,粗大钙化见于27%的结节。
  • 病理见砂粒体钙化4/15(27%)、间质钙化9/15(60%)、黏稠胶质8/15(53%)。

诊断标准与关键数值

  • 超声强回声灶按ACR TI-RADS分为4种形态模式进行分类。
  • 两名放射科医生对强回声灶存在与分布评估的观察者间一致性为53%–100%。

临床应用与阅片要点

  • 儿童甲状腺结节内强回声灶应参照ACR TI-RADS形态模式分类并记录其分布。
  • 报告点状强回声灶时不宜直接等同于砂粒体钙化,病理上多数为间质钙化或黏稠胶质。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Small echogenic foci within pediatric thyroid nodules are commonly seen by ultrasound and are one of the features used to determine the level of suspicion for malignancy. These are sometimes termed "microcalcifications," but their relation with malignancy is controversial due to the lack of standard terminology. Our aim was to evaluate sonographic patterns of echogenic foci in malignant pediatric thyroid nodules and describe the distribution of corresponding psammoma bodies and other histopathologic findings in thyroidectomy specimens.

MATERIALS AND METHODS: Ultrasounds of 15 pathologically proved malignant thyroid nodules in children were retrospectively reviewed by 2 radiologists who separately classified echogenic foci into the 4 morphologic patterns described in the American College of Radiology Thyroid Imaging, Reporting and Data System and noted their presence and distribution. Interobserver agreement was assessed, and consensus was reached for nodules for which there was disagreement. Surgical pathology findings from thyroidectomy specimens were retrospectively reviewed for the presence and distribution of psammomatous and dystrophic/stromal calcifications and eosinophilic/sticky colloid. Ultrasound and histopathologic ratings were compared, and frequencies and percentages corresponding to observed agreement levels were calculated.

RESULTS: Interobserver agreement between radiologists' sonographic assessments for the presence and distribution of echogenic foci ranged from 53% to 100% for all categories. Punctate echogenic foci were present in all nodules, and macrocalcifications, in 27%. Histopathology of the 15 nodules revealed that only 4 (27%) had psammomatous calcifications, while 9 (60%) had stromal calcifications and 8 (53%) had sticky colloid.

CONCLUSIONS: Sonographically detectable echogenic foci in malignant pediatric thyroid nodules can be reliably classified on the basis of American College of Radiology Thyroid Imaging, Reporting and Data System, with punctate echogenic foci composing the most common subtype. These echogenic foci do not represent psammomatous calcifications most of the time; instead, more than half of the malignant thyroid nodules with echogenic foci contained stromal calcifications or sticky colloid.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Erdem Toslak I, Martin B, Barkan GA, et al. Patterns of Sonographically Detectable Echogenic Foci in Pediatric Thyroid Carcinoma with Corresponding Histopathology: An Observational Study. AJNR Am J Neuroradiol. 2017. PMID: 29074635. doi:10.3174/ajnr.A5419

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。