文献速递乳腺MR

简化乳腺磁共振方案:高分辨率时间动态序列对改善病灶表征的价值

Abbreviated breast magnetic resonance protocol: Value of high-resolution temporal dynamic sequence to improve lesion characterization.
PubMed 文献 · Eur J Radiol · 2017-08-01

回顾性纳入2014年3月10日至9月22日间70例连续患者共106个组织学证实病灶(58恶性、48良性),比较FAST方案、FAST联合ULTRAFAST方案与FULL方案鉴别乳腺良恶性病灶的价值。FAST联合ULTRAFAST方案较FAST方案或FULL方案分别将特异度提高至83.3%和70.8%,敏感度不变;联合方案读片与采集时间均短于FULL方案(p<0.001)。

要点

  • FAST联合ULTRAFAST方案较FAST方案或FULL方案分别将特异度提高至83.3%和70.8%,敏感度不变。
  • 将ULTRAFAST加入FAST后,读片者1和2分别正确改变22.9%(11/48)和10.4%(5/48)良性病灶的诊断,未漏诊任何恶性病灶。
  • FAST联合ULTRAFAST方案与FAST方案的读片和图像采集时间均短于FULL方案(p<0.001)。

核心结论

  • 与FULL方案相比,在FAST方案中加入ULTRAFAST方案可提高特异度,主要体现在正确重新分类良性肿块,并缩短读片和采集时间,同时不降低敏感度。

研究设计与样本

  • 回顾性纳入2014年3月10日至9月22日间70例连续患者共106个组织学证实病灶(58恶性、48良性),均接受FULL方案(常规高分辨率动态MRI中穿插12次TRICKS采集)。

诊断标准与关键数值

  • 两名读片者分别基于TRICKS图像(ULTRAFAST)、简化方案(FAST)和全部图像(FULL方案)按BI-RADS词典将检查评为阳性或阴性并描述显著病灶。
  • FAST联合ULTRAFAST方案在所有读片者中特异度为83.3%,FAST方案或FULL方案特异度为70.8%,敏感度不变。

局限性

  • 原文为回顾性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication.

MATERIALS AND METHODS: From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test.

RESULTS: For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001).

CONCLUSION: Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Oldrini G, Fedida B, Poujol J, et al. Abbreviated breast magnetic resonance protocol: Value of high-resolution temporal dynamic sequence to improve lesion characterization. Eur J Radiol. 2017. PMID: 28987664. doi:10.1016/j.ejrad.2017.07.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。