双模态计算机辅助评估乳腺癌患者腋窝淋巴结转移:实时弹性成像与B型超声联合应用
本研究对158例乳腺癌患者的161枚腋窝淋巴结(良性69枚、转移92枚)行B型超声与实时弹性成像检查,计算机提取5个形态学特征与3个硬度特征,采用评分法和支持向量机(SVM)分类良恶性淋巴结,并与视觉评估比较。SVM联合双模态特征获得最大AUC(0.895)和准确率(85.7%),优于评分法(AUC=0.881;ACC=83.6%)、视觉评估(AUC=0.830;ACC=84.5%)及所有单模态方法。结论认为双模态特征有助于鉴别良恶性淋巴结,SVM表现最佳,计算机辅助双模态评估可能用于日常临床实践。
要点
- SVM联合双模态特征的AUC为0.895、准确率85.7%,优于评分法和视觉评估。
- 所有单模态特征在良恶性淋巴结间差异均有统计学意义(p<0.001)。
- 留一交叉验证下SVM双模态特征准确率仍达84.5%。
核心结论
- 计算机辅助从实时弹性成像和B型超声提取的双模态特征有助于鉴别良恶性腋窝淋巴结,SVM双模态方法优于评分法、视觉评估及所有单模态方法,可能用于乳腺癌腋窝转移的日常临床评估。
研究设计与样本
- 研究纳入158例乳腺癌患者的161枚腋窝淋巴结(良性69枚、转移92枚),均行B型超声和实时弹性成像检查;计算机从B型超声提取5个形态学特征(描述淋巴结门、大小、形状和回声均匀性),从实时弹性成像提取3个硬度特征;采用评分法和支持向量机(SVM)两种计算机分类方法,并与视觉评估法比较。
关键影像表现/征象
- B型超声提取的5个形态学特征描述淋巴结的门、大小、形状和回声均匀性。
- 实时弹性成像提取3个硬度特征用于量化淋巴结硬度。
- 所有特征在良性与转移性淋巴结间差异均有统计学意义(p<0.001)。
诊断标准与关键数值
- 单特征最高AUC为0.803,最高准确率为75.2%。
- SVM双模态特征:AUC=0.895,ACC=85.7%。
- 评分法:AUC=0.881,ACC=83.6%。
- 视觉评估法:AUC=0.830,ACC=84.5%。
- 留一交叉验证下SVM双模态特征ACC为84.5%。
临床应用与阅片要点
- 计算机辅助双模态评估可能用于乳腺癌患者腋窝转移的日常临床评估。
- SVM双模态方法在AUC和准确率上优于评分法和视觉评估法,也优于所有单模态方法。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To propose a computer-assisted method for quantifying the hardness of an axillary lymph node on real-time elastography (RTE) and its morphology on B-mode ultrasound; and to combine the dual-modal features for differentiation of metastatic and benign axillary lymph nodes in breast cancer patients.
MATERIALS AND METHODS: A total of 161 axillary lymph nodes (benign, n=69; metastatic, n=92) from 158 patients with breast cancer were examined with both B-mode ultrasound and RTE. With computer assistance, five morphological features describing the hilum, size, shape, and echogenic uniformity of a lymph node were extracted from B-mode, and three hardness features were extracted from RTE. Single-modal and dual-modal features were used to classify benign and metastatic nodes with two computerized classification approaches, i.e., a scoring approach and a support vector machine (SVM) approach. The computerized approaches were also compared with a visual evaluation approach.
RESULTS: All features exhibited significant differences between benign and metastatic nodes (p<0.001), with the highest area under the receiver operating characteristic curve (AUC) of 0.803 and the highest accuracy (ACC) of 75.2% for a single feature. The SVM on dual-modal features achieved the largest AUC (0.895) and ACC (85.7%) among all methods, exceeding the scoring (AUC=0.881; ACC=83.6%) and the visual evaluation methods (AUC=0.830; ACC=84.5%). With the leave-one-out cross validation, the SVM on dual-modal features still obtained an ACC as high as 84.5%.
CONCLUSION: Dual-modal features can be extracted from RTE and B-mode ultrasound with computer assistance, which are valuable for discrimination between benign and metastatic lymph nodes. The SVM on dual-modal features outperforms the scoring and visual evaluation methods, as well as all methods using single-modal features. The computer-assisted dual-modal evaluation of lymph nodes could be potentially used in daily clinical practice for assessing axillary metastasis in breast cancer patients.
引用
- Zhang Q, Suo J, Chang W, et al. Dual-modal computer-assisted evaluation of axillary lymph node metastasis in breast cancer patients on both real-time elastography and B-mode ultrasound. Eur J Radiol. 2017. PMID: 28987700. doi:10.1016/j.ejrad.2017.07.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。