文献速递乳腺MR

背景实质强化对社区医疗实践中乳腺MR成像判读性能的影响

Effect of Background Parenchymal Enhancement on Breast MR Imaging Interpretive Performance in Community-based Practices.
PubMed 文献 · Radiology · 2017-10-25

该研究分析了2010年1月至2012年10月在旧金山湾区六家机构2958名女性的3770次乳腺MR检查,比较低背景实质强化(轻微或轻度)与高背景实质强化(中度或显著)对判读性能的影响。结果显示高背景实质强化与更高的异常判读率和活检推荐率及更低的特异度相关,而癌检出率无显著差异。

要点

  • 高背景实质强化(中度或显著)较低背景实质强化(轻微或轻度)在筛查和诊断MR中均表现为异常判读率和活检推荐率升高、特异度降低。
  • 筛查MR中低背景实质强化组特异度89%(95%CI:87,91) vs 高背景实质强化组75%(95%CI:71,80),P=0.01。
  • 诊断MR中低背景实质强化组特异度86%(95%CI:84,88) vs 高背景实质强化组75%(95%CI:74,82),P<0.001。

核心结论

  • 相较于背景实质强化轻微或轻度的MR检查,背景实质强化中度或显著的检查与更高的异常判读率和活检推荐率及更低的特异度相关,癌检出率无差异。

研究设计与样本

  • 多机构队列分析,纳入2010年1月至2012年10月旧金山湾区六家参与机构的2958名女性的3770次乳腺MR检查,结果前瞻性记录于旧金山乳腺X线摄影登记处,采用二项比例检验比较低背景实质强化(轻微或轻度)与高背景实质强化(中度或显著)组间的性能指标。

诊断标准与关键数值

  • 筛查MR中,低背景实质强化组异常判读率为157/1301(12%),高背景实质强化组为111/424(26%),P<0.001。
  • 筛查MR中,低背景实质强化组活检推荐率为85/1301(7%),高背景实质强化组为54/424(13%),P<0.001。
  • 筛查MR中,低背景实质强化组特异度为89%(95%CI:87,91),高背景实质强化组为75%(95%CI:71,80),P=0.01。
  • 诊断MR中,低背景实质强化组活检推荐率为325/1443(23%),高背景实质强化组为195/601(32%),P<0.001。
  • 诊断MR中,低背景实质强化组特异度为86%(95%CI:84,88),高背景实质强化组为75%(95%CI:74,82),P<0.001。

临床应用与阅片要点

  • 筛查MR中,低背景实质强化组敏感度为76%(95%CI:55,91),高背景实质强化组为83%(95%CI:52,98),P=0.94。
  • 诊断MR中,低背景实质强化组敏感度为93%(95%CI:87,97),高背景实质强化组为96%(95%CI:87,99),P=0.69。
  • 筛查MR中,低背景实质强化组每1000例癌检出率为15例,高背景实质强化组为24例,P=0.30。
  • 诊断MR中,低背景实质强化组每1000例癌检出率为78例,高背景实质强化组为85例,P=0.64。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the effect of background parenchymal enhancement (BPE) on breast magnetic resonance (MR) imaging interpretive performance in a large multi-institutional cohort with independent analysis of screening and diagnostic MR studies. Materials and Methods Analysis of 3770 breast MR studies was conducted. Examinations were performed in 2958 women at six participating facilities in the San Francisco Bay Area from January 2010 to October 2012. Findings were recorded prospectively in the San Francisco Mammography Registry. Performance measures were compared between studies with low BPE (mild or minimal) and those with high BPE (moderate or marked) by using binomial tests of proportions. Results Of 1726 MR imaging studies in the screening group, 1301 were classified as having low BPE and 425 were classified as having high BPE (75% vs 25%, respectively; P < .001). Of 2044 MR imaging studies in the diagnostic group, 1443 were classified as having low BPE and 601 were classified as having high BPE (71% vs 29%, respectively; P < .001). For low versus high BPE groups at screening, abnormal interpretation rate was 157 of 1301 versus 111 of 424 (12% vs 26%, P < .001); biopsy recommendation rate was 85 of 1301 versus 54 of 424 (7% vs 13%, P < .001); and specificity was 89% (95% confidence interval [CI]: 87, 91) versus 75% (95% CI: 71, 80) (P = .01). For the low versus high BPE groups at diagnostic MR imaging, biopsy recommendation rate was 325 of 1443 versus 195 of 601 (23% vs 32%, P < .001); and specificity was 86% (95% CI: 84, 88) versus 75% (95% CI: 74, 82) (P < .001). There were no significant differences between studies with low versus high BPE in sensitivity for screening (76% [95% CI: 55, 91] vs 83% [95% CI: 52, 98]; P = .94) or diagnostic (93% [95% CI: 87, 97] vs 96% [95% CI: 87, 99]; P = .69) MR imaging, nor were there significant differences in cancer detection rate per 1000 patients between the low BPE versus high BPE groups for screening (15 per 1000 vs 24 per 1000, P = .30) or diagnostic (78 per 1000 vs 85 per 1000, P = .64) MR imaging. Conclusion Relative to MR studies with minimal or mild BPE, those with moderate or marked BPE were associated with higher abnormal interpretation and biopsy rates and lower specificity, with no difference in cancer detection rate. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Ray KM, Kerlikowske K, Lobach IV, et al. Effect of Background Parenchymal Enhancement on Breast MR Imaging Interpretive Performance in Community-based Practices. Radiology. 2017. PMID: 29072981. doi:10.1148/radiol.2017170811

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。